Fixes are available
Fix packs for DataPower B2B Appliance version 6.0
Fix packs for DataPower Integration Appliance version 6.0
Fix packs for DataPower Service Gateway version 6.0
Fix packs for DataPower Service Gateway version 6.0.1
Fix packs for DataPower B2B Appliance version 6.0.1
Fix packs for DataPower Integration Appliance version 6.0.1
APAR status
Closed as program error.
Error description
When a request is sent to a backend, the response triggers DataPower's backend timeout due to the response containing transfer encoding or other certain headers as part of the connection header.
Local fix
A possible workaround is to use HTTP/1.0 on the backend.
Problem summary
Affected is processing of HTTP responses with ?Connection? header. HTTP servers that put the transfer encoding or other certain headers in a Connection header might result in errors decoding the response data among other effects.
Problem conclusion
Fix is available in 5.0.0.14, 6.0.0.6 and 6.0.1.2. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC99761
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
402
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-02-28
Closed date
2014-05-05
Last modified date
2014-05-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
999
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R601 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.0.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
11 February 2022