IBM Support

IC99108: EDIFACT CONTRL MESSAGE NOT GENERATED CORRECTLY WHEN WTX MAP IS USED IN INBOUND ENVELOPE.

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • EDIFACT CONTRL message is not generated correctly when a WTX map
    is used with an inbound envelope.
    An inbound EDIFACT message is received with a missing BGM
    segment.
    The envelope parameters are defined to generate an outbound
    CONTRL.
    The CONTRL is generated like this:
    UNB+UNOB:4+SARSZA+DGA+20131009:1537+17++CONTRL++++1'
    UNH+1+CONTRL:D:3:UN'
    UCI+20130917150813+DGA+SARSZA+7'
    UCM+20728212154145+GOVCBR:D:11B:UN:C2CUB+4'
    UNT+4+1'
    UNZ+1+17'
    
    However, it should contain a UCS segment to indicate the BGM is
    missing:
    UCS+2+13'
    
    The WTX translation report looks okay and it does correctly
    identify the missing BGM, but this information is not
    passed back to Sterling B2B Integrator so that the CONTRL is
    generated correctly.
    

Local fix

  • Workaround:
    None
    

Problem summary

  • Users Affected:
    Inbound EDIFACT processing customers who use WTX compliance
    checking.
    
    Problem Description:
    EDIFACT CONTRL message is not generated with entries from the
    WTX ACK that was created during the WTX compliance step.
    
    Platforms Affected:
    All
    

Problem conclusion

  • Resolution Summary:
    A code fix was provided.
    
    Delivered In:
    5020500_5
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC99108

  • Reported component name

    STR B2B INTEGRA

  • Reported component ID

    5725D0600

  • Reported release

    524

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-01-31

  • Closed date

    2015-05-13

  • Last modified date

    2015-05-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PI21673

Fix information

  • Fixed component name

    STR B2B INTEGRA

  • Fixed component ID

    5725D0600

Applicable component levels

  • R525 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.4","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date: