Fixes are available
APAR status
Closed as program error.
Error description
When using DataPower's flow control feature, DataPower might buffer the data instead of streaming it as expected.
Local fix
Problem summary
Affected is the use of flow control function. Attachment flow control does not work for SOAP with Attachment (SwA) request messages with attachments.
Problem conclusion
Fix is available in 6.0.1.1. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC99028
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
601
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-01-28
Closed date
2014-03-04
Last modified date
2014-03-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R601 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
11 February 2022