  • Closed as program error.

Error description

  • If multiple concurrent transfer requests are submitted then
    some of the transfers could result in failure due to sharing
    of resources across the multiple transfers.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    Users of WebSphere MQ File Transfer Edition on IBM i
    attempting to perform concurrent physical file member transfers.
    
    
    Platforms affected:
    IBM iSeries
    
    ****************************************************************
    PROBLEM SUMMARY:
    The File Transfer Edition code was sharing resources across
    concurrent multiple physical file member transfers, which, in
    some cases, could result in empty members.
    

Problem conclusion

  • WebSphere MQ File Transfer Edition has been modified to
    instantiate new resources for each physical file member
    transfer, thereby mitigating the possibility of empty member
    sets.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v7.0       7.0.4.4
    
    The latest available maintenance can be obtained from
    'WebSphere MQ Recommended Fixes'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037
    
    If the maintenance level is not yet available information on
    its planned availability can be found in 'WebSphere MQ
    Planned Maintenance Release Dates'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC94677

  • Reported component name

    WMQ FILE TRANSF

  • Reported component ID

    5724R1000

  • Reported release

    704

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-08-06

  • Closed date

    2013-08-30

  • Last modified date

    2013-08-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WMQ FILE TRANSF

  • Fixed component ID

    5724R1000

Applicable component levels

  • R704 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSEP7X","label":"WebSphere MQ File Transfer Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0.4","Edition":"","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]