Fixes are available
APAR status
Closed as program error.
Error description
If an MQRFH2 header contains non-safe-to-print data this might disable the operation of the DataPower multi-step probe.
Local fix
Problem summary
Customers who use the MQ Protocol Front Side Handler are likely to see this problem. The MQRFH2 header might not be handled correctly if its NameValueData field contains non-safe-to-print data.
Problem conclusion
Fix is available in 5.0.0.11 and 6.0.0.3. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC94315
Reported component name
DATAPOWER BLAD
Reported component ID
DPBLADE01
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-07-23
Closed date
2013-10-15
Last modified date
2013-11-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER BLAD
Fixed component ID
DPBLADE01
Applicable component levels
R500 PSY
UP
R600 PSY
UP
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSFGB5","label":"WebSphere DataPower Integration Blade XI50B"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.0.0","Edition":"","Line of Business":{"code":"LOB15","label":"Integration"}}]