Fixes are available
APAR status
Closed as program error.
Error description
Installed Pcomm 6.0.7 and tried the new utility pcssound.exe. However, I found problems. . 1. The registry keys for Pcomm sound events are installed as below. HKEY_CURENT_USER AppEvents Schemes Apps PComm pcsSoundxxxxxxxxxxx .current .modified . If I remove some pcsSoundxxxxxxxxx keys and execute pcssound.exe /b to restore default settings, the following messages are displayed and the lacked settings were not restored. . Error: Failed to open key ( AppEvents\Schemes\Apps\PComm \pcsSoundxxxxxxxxx\.current ) Error Code : 0 . 2. pcssound.exe /s <filename> to save the current settings always traps just after displaying "Saving sound settings from to pcssound.csv file". It occurs regardless of specifying filename or not.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of PCSSOUND utility * **************************************************************** * PROBLEM DESCRIPTION: 1) All default sound settings are not * * restored using the /b option. * * 2) Trap occurs when using /s option. * **************************************************************** * RECOMMENDATION: * **************************************************************** When PCSSOUND /b option is used to restore the default sound settings in the registry, any missing registry keys are not restored. When PCSSOUND /s option is used to save the sound settings to an external file, a trap occurs and the external file is not created.
Problem conclusion
PCSSOUND.EXE has been changed to correct these errors. The original function of the utility remains the same as it is documented in IC88030. Fix scheduled for PCOM 6.0.8 Refresh Pack
Temporary fix
Comments
APAR Information
APAR number
IC92915
Reported component name
PCOMM V5 COMBO-
Reported component ID
5639I7000
Reported release
601
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-06-07
Closed date
2013-06-12
Last modified date
2013-08-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PCSSOUND
Fix information
Fixed component name
PCOMM V5 COMBO-
Fixed component ID
5639I7000
Applicable component levels
R601 PSY
UP
R602 PSY
UP