Error description
Process Designer crashes when used for a prolonged time. The crash manifests itself in two different ways, 1. Generates dumps 2. Crashes without any evidence of dumps Note: Increasing heapsize prolongs the time before crash.
Local fix
Problem summary
Out of Memory in Process Designer may occur on IE9 after a period of time. USER AFFECTED: Business Process Manager Advanced, Standard and Express Process Designer users PROBLEM DETAILED DESCRIPTION: Due to a memory leak in the SWT browser working within IE9, specifically , Out of Memory may occur after a period of time, crashing Process Designer. Identification of the issue is tied to the IE version.
Problem conclusion
Code path was changed so the native browser gets used, i.e. javascript invoked, only when Library gets modified. FIX AVAILABILITY: Fix for 8.0.1.1 is available on Fix Central. Search for IC92483. When download fix package from Fix Central, please ensure that the complimentary readme is also downloaded, as well as any pre-requisites' readmes, and they are reviewed thoroughly.
Temporary fix
Comments
APAR Information
APAR number
IC92483
Reported component name
PROCESS DESIGNE
Reported component ID
5725C9701
Reported release
750
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-05-22
Closed date
2013-08-27
Last modified date
2013-08-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
PROCESS DESIGNE
Fixed component ID
5725C9701
Applicable component levels
R750 PSN
UP
R751 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSFTUY","label":"IBM Business Process Manager Tools and Add-Ons"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
07 January 2022