Direct links to fixes
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if007
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if010
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if015
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if017
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if022
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if028
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if008
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if009
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if013
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if015
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if018
Sterling Connect:Direct for Microsoft Windows 4.6.0 Fix Packs
APAR status
Closed as program error.
Error description
Running CD Configuration Utility in GUI mode, it fails to extract configuration when the user has no write permission to the registry: "The node specified by CDNODE - v4.6.00 was not found in the registry" The same operation succeeds when running in quiet mode.
Local fix
STRRTC - 351347 SF / SF Circumvention: given Full Control permission to the Regsitry hive HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Sterling Commerce and Full Control to the <Installation Drive>:\Program Files (x86)\Sterling Commerce\Connect Direct v4.6.00\Server folder
Problem summary
Users Affected: Sterling Connect:Direct for Windows 4.5.00 Sterling Connect:Direct for Windows 4.5.01 Sterling Connect:Direct for Windows 4.6.0 Problem Description: Running CD Configuration Utility in GUI mode, it fails to extract configuration when the user has no write permission to the registry: "The node specified by CDNODE - v4.6.00 was not found in the registry". The same operation succeeds when running in quiet mode. Platforms Affected: Windows
Problem conclusion
Resolution Summary: Removed the need for write access in GUI mode and also enhanced the displayed error message to include the reason for the failure, like Access is denied. Delivered In: Sterling Connect:Direct for Windows 4.5.00 Build 051 Fix 88 Sterling Connect:Direct for Windows 4.5.01 Build 017 Fix 54 Sterling Connect:Direct for Windows 4.6.0.2_iFix011
Temporary fix
Run CD Configuration Utility from a command prompt in quiet mode, like "CDConfig.exe /q /uUser.cfg" or "CDConfig.exe /q /mMap.cfg"
Comments
APAR Information
APAR number
IC86986
Reported component name
STR CD FOR WIND
Reported component ID
5725C9908
Reported release
460
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-10-04
Closed date
2012-10-15
Last modified date
2012-10-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR CD FOR WIND
Fixed component ID
5725C9908
Applicable component levels
Document Information
Modified date:
25 August 2023