APAR status
Closed as program error.
Error description
Error Description￘ AS2 input message to B2B gateway containing a "0" as the final password character caused DataPower to restart when the WTX transform code attempted to check the EDIFACT data for padding. Zero was the only character to cause this problem.
Local fix
Local Fix￘ Change password to a string not ending in "0"
Problem summary
DataPower customer who set the recipient reference password in AS2 request is likely to see this problem. Processing the AS2 request in B2B gateway a restart might occur if the password is ending with "0" for the recipient reference password.
Problem conclusion
The fix is available on 3.8.2.14, 4.0.1.12, 4.0.2.8 and 5.0.0.1.
Temporary fix
Comments
APAR Information
APAR number
IC84689
Reported component name
DATAPWER B2B XB
Reported component ID
DP1234B2B
Reported release
402
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-06-18
Closed date
2012-07-18
Last modified date
2012-08-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPWER B2B XB
Fixed component ID
DP1234B2B
Applicable component levels
R382 PSY
UP
R401 PSY
UP
R402 PSY
UP
R500 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSQ3J2","label":"WebSphere DataPower B2B Appliance XB60"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.0.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
21 August 2012