APAR status
Closed as program error.
Error description
Error Description: On Backout, IBM Sterling B2B Integrator Websphere MQ Adapter Receive and Async Receive functions did not make use of the queue attributes "backout threshold" and "backout queue name" of the Websphere MQ queue. After the number of get attempts defined in "backout threshold", the message read should not be rolled back to the original queue, but must be put to the queue defined in "backout queue name". An indefinite number of read attempts should only be made if the "backout threshold" has the value of 0.
Local fix
Local Fix: SF - SF STRRTC - 322546 circumvention none
Problem summary
Users Affected: All Problem Description: Handling of poison messages arrived at WSMQ server queue using WebSphere MQ Adapter. Platforms Affected: All
Problem conclusion
Resolution Summary: A code fix is provided. By setting the value backoutEnabled=true, the poison messages go to backout queue. Delivered In: 5020500_16 5020603_3
Temporary fix
Comments
APAR Information
APAR number
IC83788
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
521
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-05-27
Closed date
2017-07-12
Last modified date
2019-03-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date: