IC83589: WEBSPHERE MQ EXPLORER 7.1: ERROR WHEN CHANGING "LOGGER EVENTS" TO "ENABLED" IN THE EVENTS PROPERTY PAGE FOR A QUEUE MANAGER

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Using WebSphere MQ Explorer V7.1, in the left navigation panel
    select a queue manager and display the Properties.  Then select
    the page: Events.
    
    Changing the attribute for the "Logger events" to "Enabled"
    from the default "Disabled", results in the following error
    message being displayed:
    
    Error applying changes from page "Events"
    Reason: The value of one of the properties specified
    is not valid. The request was not processed (AMQ4126).
    
    The change to "Enabled" for all the other fields in that page
    works without an error message.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    This issue affects users of the WebSphere MQ V7.1 and V7.5
    Explorer who want to modify the Logger events attribute
    (LOGGEREV) of a queue manager which has been configured to use
    circular logging.
    
    Platforms affected:
    Linux (Power),Linux (x86),Linux (x86-64),Linux (zSeries),
    Windows
    
    ****************************************************************
    PROBLEM SUMMARY:
    WebSphere MQ queue managers that use linear logging can be
    configured to generate logger events when the queue manager
    starts writing log records to a new log extent or, on IBM i,
    to a new journal receiver.
    
    When the Logger events attribute (LOGGEREV) is modified using
    WebSphere MQ Explorer, a PCF command message is sent to the
    queue manager specifying the new value. The queue manager
    processes the PCF message and sets the value of LOGGEREV to
    either:
    
    ENABLED
    
    or
    
    DISABLED
    
    as appropriate.
    
    WebSphere MQ Explorer did not check the logging mode of the
    queue manager before sending the PCF message. If the queue
    manager had been configured to use circular logging, then the
    PCF command message could not be processed by the queue manager
    and an error would be returned to the WebSphere MQ Explorer.
    This caused the WebSphere MQ Explorer to display the following
    error message:
    
    Error applying changes from page "Events"
    Reason: The value of one of the properties specified
    is not valid. The request was not processed (AMQ4126).
    

Problem conclusion

  • The WebSphere MQ Explorer has been updated so that the Logger
    Events attribute (LOGGEREV) can only be modified for local
    queue managers if the queue manager the WebSphere MQ Explorer
    is connected to has been configured to use linear logging.
    
    If WebSphere MQ Explorer is connected to a local queue manager
    that has been configured to use circular logging, the text:
    
    Logger Events are only valid when using a linear logging
    queue manager.
    
    is displayed on the Events page next to the "Logger events:"
    label.
    
    It is not possible for WebSphere MQ Explorer to check if a
    remote queue manager has been configured to use linear or
    circular logging.  When WebSphere MQ Explorer is connected to a
    remote queue manager, the text:
    
    Logger Events are only valid when using a linear logging
    queue manager.
    
    is displayed beneath the drop down list for the Logger Events
    attribute.  This acts as a prompt for users to check that the
    remote queue manager has been configured to use linear logging
    before trying to enable Logger Events.
    
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
                       v7.1
    Platform           Fix Pack 7.1.0.3
    --------           --------------------
    Windows            7.1.0.3
    Linux (x86)        7.1.0.3
    Linux (x86-64)     7.1.0.3
    Linux (zSeries)    7.1.0.3
    Linux (Power)      7.1.0.3
    
    Platform           v7.5
    --------           --------------------
    Multiplatforms     7.5.0.1
    
    The latest available maintenance can be obtained from
    'WebSphere MQ Recommended Fixes'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037
    
    If the maintenance level is not yet available information on
    its planned availability can be found in 'WebSphere MQ
    Planned Maintenance Release Dates'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC83589

  • Reported component name

    WMQ WINDOWS V7

  • Reported component ID

    5724H7220

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-05-18

  • Closed date

    2012-08-28

  • Last modified date

    2012-08-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WMQ WINDOWS V7

  • Fixed component ID

    5724H7220

Applicable component levels

  • R710 PSY

       UP