IBM Support

IC82657: CLIENT RECEIVING JAVASCRIPT ERROR WHEN NAVIGATING TO INPUT FIELD. OBJECT EXPECTED LXGWFUNCTIONS.JS CODE: 0

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The nextInputField function is expecting 4 parameters to be
    passed to it but only 3 are passed.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: HATS users with the auto advance             *
    *                 functionality enabled in the project.        *
    ****************************************************************
    * PROBLEM DESCRIPTION: When the auto advance option is         *
    *                      enabled in HATS, and the application    *
    *                      is run using Internet Explorer, a       *
    *                      JavaScript error can occur in certain   *
    *                      situations when a page is submitted.    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    In lxgwfunctions.js, the nextInputField function was being
    called from caretTracking; however, it was not passing the
    correct number of parameters to the function.  In some
    situations, when the page was submitted, a JavaScript error
    could occur.
    

Problem conclusion

  • The nextInputField calls we cleaned up to pass the correct
    parameters to prevent the error.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC82657

  • Reported component name

    RATL HATS MULTI

  • Reported component ID

    5724U6700

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-04-13

  • Closed date

    2012-04-27

  • Last modified date

    2012-04-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • HATSCOMM
    

Fix information

  • Fixed component name

    RATL HATS MULTI

  • Fixed component ID

    5724U6700

Applicable component levels

  • R750 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXKAY","label":"IBM Host Access Transformation Services"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]