APAR status
Closed as program error.
Error description
In firmware 4.0.x, when you set 'Permit Connections to insecure SSL Servers' to ON from a service object (for example, a MultiProtocol Gateway configuration page), it can revert back to OFF, after you apply the change. To make sure this option is enabled, browse Objects -> Crypto Configuration -> SSL Proxy Profile -> MySSLProxy and verify this option is set to ON. As an alternative you can use the CLI to check if this setting is enabled: show sslproxy mySSLProxy
Local fix
Set option via the Objects menu or CLI
Problem summary
The value for 'Permit Connections to Insecure SSL Server' in the MPGW or WAG Task Template may be incorrect if there are multiple SSL Proxy Profiles associated with this service. This condition would occur if, for example, an HTTPS FSH is configured for the service. In this case, the value displayed for the field might be that of the SSL Proxy Profile associated with the HTTPS FSH rather than the value of the SSL Proxy Profile of the service. This fix ensures that the value being displayed for this field is that of the SSL Proxy Profile directly associated with the service.
Problem conclusion
The fix is available in 4.0.1.10 and 4.0.2.6
Temporary fix
Comments
APAR Information
APAR number
IC81564
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
382
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-02-22
Closed date
2012-04-12
Last modified date
2012-05-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R401 PSY
UP
R402 PSY
UP
R500 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]