IBM Support

IC81564: ENABLING "PERMIT CONNECTIONS TO INSECURE SSL SERVERS" FROM SERVICE OBJECT MIGHT REVERT TO DISABLED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In firmware 4.0.x, when you set 'Permit Connections to
    insecure SSL Servers' to ON
    from a service object (for example, a MultiProtocol Gateway
    configuration
    page), it can revert back to OFF, after you apply the change.
    
    To make sure this option is enabled, browse Objects -> Crypto
    Configuration -> SSL Proxy Profile -> MySSLProxy and verify
    this option is set to ON.
    
    As an alternative you can use the CLI to check if this setting
    is enabled:
    
    show sslproxy mySSLProxy
    

Local fix

  • Set option via the Objects menu or CLI
    

Problem summary

  • The value for 'Permit Connections to Insecure
    SSL Server' in the MPGW or WAG Task Template may be incorrect if
    there are multiple SSL Proxy Profiles associated with this
    service.  This condition would occur if, for example, an HTTPS
    FSH is configured for the service.  In this case, the value
    displayed for the field might be that of the SSL Proxy
    Profile associated with the HTTPS FSH rather than the value
    of the SSL Proxy Profile of the service.
    
    This fix ensures that the value being displayed for this field
    is that of the SSL Proxy Profile directly associated with the
    service.
    

Problem conclusion

  • The fix is available in 4.0.1.10 and 4.0.2.6
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC81564

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    382

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-02-22

  • Closed date

    2012-04-12

  • Last modified date

    2012-05-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R401 PSY

       UP

  • R402 PSY

       UP

  • R500 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]