IBM Support

IC80942: WEBSPHERE MQ V5.3 SETMQAUT WITH +NONE FAILS WITH AMQ7097 AUTHORIZATION SPECIFICATION THAT IS NOT VALID.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Using the setmqaut command with commands generated by amqoamd
    results in a failure e.g
    
    "setmqaut -m qmgrname -n name -t queue -g group +None"
    returns:
    "AMQ7097: You gave an authorization specification that is not
    valid."
    

Local fix

  • Edit the output generated by amqoamd to replace "+None" by
    "+none".   The setmqaut command will then work as intended.
    

Problem summary

  • Running the amqoamd command produces output with "setmqaut with
    authorization specification as +None" for objects that have no
    authorization specified. When these setmqaut commands are run to
    set the object authorization later, the command fails.
    

Problem conclusion

  • The setmqaut commands were created with authorization "+None".
    The correct authorization for objects with no authorization is
    "+none" ( lowercase none). Correct the code that creates the
    setmqaut command to produce authorization with +none instead of
    +None.
    

Temporary fix

  • Modify the setmqaut commands created by the amqoamd and replace
    +None to +none for objects that have no specific authorization.
    

Comments

APAR Information

  • APAR number

    IC80942

  • Reported component name

    WEBS MQ NSS ITA

  • Reported component ID

    5724A3902

  • Reported release

    531

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-01-20

  • Closed date

    2012-01-20

  • Last modified date

    2012-01-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBS MQ NSS ITA

  • Fixed component ID

    5724A3902

Applicable component levels

  • R531 PSY

       UP

[{"Line of Business":{"code":"LOB36","label":"IBM Automation"},"Business Unit":{"code":"BU053","label":"Cloud \u0026 Data Platform"},"Product":{"code":"SSFKSJ","label":"WebSphere MQ"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.1"}]

Document Information

Modified date: