Error description

  • If a DNS Static Host or Host Alias is configured to point to
    127.0.0.1 and that is used in the Web Service Proxy
    configuration as the wsdl source-location, the Web Service Proxy
    configuration may fail to retrieve the WSDL file.
    
    This may result in the Web Service Proxy reporting the WSDL
    Status as "Error" and displaying the message:
    
    "There was an error while reading WSDL: '<URL>'"
    
    The logs may show:
    
    "Waiting for route to '<localhost>' to complete network
    dependent management event."
    
    "The wsdl '<wsdl>' could not be parsed or failed validation."
    

Local fix

  • To workaround:
    
    a) Explicitly define the IP address as 127.0.0.1 in the WSDL
    Source Location instead of a DNS Static Host or Host Alias.
    
    b) Use an explicitly configured IP address on one of the
    interfaces in the DNS Static Host or Host Alias instead of
    127.0.0.1
    
    c) Store the file in a local directory and use the file location
    similar to: local:///mylocal.wsdl instead of a "remote"
    protocol.
    

Problem summary

  • The problem will be fixed in a future release by skipping the
    network detection if the IP address is on the loopback
    interface.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IC76498

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    382

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-05-19

  • Closed date

    2011-06-02

  • Last modified date

    2011-06-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • R382 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]