  • Pcom 6.0.1 Japanese
    3270 session causes application error if enabling "Blink Cursor"
    Steps.
    1. Open a 3270 session and select
       Edit -> Settings -> appearance -> display settings
       and set "blink cursor" on.
    2. Press OK to return to session screen (The session does not
       fail at this point.)
    3. Save the .WS and close the session
    4. Open the session again from the .WS.
    5. Application error popup appears after displaying host
       intial screen in a moment.
    .
    Customer said that this was not occur when she was using
    Pcom 6.0.0.
    In my test on Pcom 6.0.1, it occurs on 3270 session but
    on 5250 session.
    

Local fix

  • Disable blink cursor
    

Problem summary

  • 3270 Session fail when start with blink cursor
     selected.
    Problem cause : Invalid variable address was referenced and whic
    h should only for 5250 session. Problem occur after APAR SE43154
    .
    

Problem conclusion

  • Exclude the condition for 3270 session.
    

Temporary fix

  • Yes
    

Comments

APAR Information

  • APAR number

    IC70939

  • Reported component name

    PCOMM V5 COMBO-

  • Reported component ID

    5639I700J

  • Reported release

    601

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-09-03

  • Closed date

    2010-09-03

  • Last modified date

    2010-09-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IP23316

Modules/Macros

  • PCSWS
    

Fix information

  • Fixed component name

    PCOMM V5 COMBO-

  • Fixed component ID

    5639I700J

Applicable component levels

  • R601 PSN

       UP

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSEQ5Y","label":"Personal Communications"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
06 January 2022