IBM Support

IC68105: INCORRECT CODE RETURNED DURING SILENT INSTALLATION

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • After a  silent installation, the error return code from the
    msiexec process can be overrided by an internal warning code.
    As an example, if you are doing a silent installation on a
    unsupported platform, the error returned code value will be 1
    (the action returns a warning), when the msiexec process will
    return 1603 (A fatal error occurred.)
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * WINDOWS                                                      *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * After a  silent installation, the error return code from     *
    * themsiexec process can be overrided by an internal           *
    * warningcode.As an example, if you are doing a silent         *
    * installation on aunsupported platform, the error returned    *
    * code value will be1  (the action returns a warning), when    *
    * the msiexec processwill return 1603 (A fatal error           *
    * occurred.)                                                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to 9.5 FP6 or later                                  *
    ****************************************************************
    

Problem conclusion

  • With DB2 9.5 FP6, whenever possible a specific error code is
    returned.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC68105

  • Reported component name

    DB2 FOR LUW

  • Reported component ID

    DB2FORLUW

  • Reported release

    950

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-04-22

  • Closed date

    2010-05-25

  • Last modified date

    2010-08-25

  • APAR is sysrouted FROM one or more of the following:

    IC68096

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • R950 PSY

       UP

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSEPGG","label":"DB2 for Linux- UNIX and Windows"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.5"}]

Document Information

Modified date: