  • Closed as microcode or hardware problem.

Error description

  • When using the McDATA SMI Agent for EOS, the Topology Viewer may
    show some connections from switch ports to subsystem ports as
    black lines (indicating missing) or not at all.
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • Users Affected:
    All customers running TPC and using Brocade EOS SMI Agent 2.7.
    
    Problem Description:
    After running a CIMOM Discovery and Fabric Probe for this
    fabric, not all switch port to subsystem port connections
    could be retrieved by TPC. This is an issue with the Brocade
    EOS SMI Agent 2.7 that has been reported to Brocade.  The user
    most likely will notice this when looking in the Topology
    Viewer Switch view that shows the connections from the switch
    to the connected devices. It's very likely that there is a
    mismatch between what TPC and the Element Manager or EFCM/DCFM
    show regarding the connections.
    
    This is known to occur while monitoring the Intrepid 10000, but
    may occur with other switches too.
    
    Summary of fix:
    The fix for this from Brocade is unknown at this time.  However,
    there is a workaround for this issue from the TPC side. For
    the fabric probe in TPC, two different algorithms can be used.
    This issue only occurs with one of the algorithms, but
    unfortunately is is the default one when the probe is created.
    Therefore, it's necessary to switch to the alternate approach
    after the probe has run for the first time.
    
    Here are the steps:
    
    1. Create a fabric probe as usual
    2. Save the job configuration -> the probe will automatically
    be submitted
    3. After the probe is finished use the TPC CLI as following:
    - Open a Command Window  or Command Shell in the
    Operating System
    - cd C:\Prorgam Files\IBM\TPC\cli or cd
    /opt/IBM/TPC/cli
    -> if TPC is installed in a non-default path use this one here
    - tpctool -url localhost:9550 -user <user> -pwd <password>
    ->  the user and password are the same used to logon in TPC GUI
    - tpctool> setfpplcy -fabric <fabric ww> -property CIM_ALG 0
    -> use the fabric wwn for the Intrepid 10000 Director switch
    4. After this command finishes successfully, go to TPC GUI and
    submit the probe again
    5. Check the probe logfile named like
    user.probe_fabric_ProbeFabrics.xx.xx.log to have following
    messages in it:
    
    BTAFM0614I The task is to probe topology and zoning.
    The probe algorithm is CIM association.
    
    6. After the probe finishes successfully, all port to port
    connections should be displayed in TPC.
    
    Please notice that after switching to the alternate probe
    approach, the run time of the probe will increase
    significantly. This is because the alternate approach is
    memory optimized and the default approach is run time
    optimized.   Refer also to APAR IC68617 regarding a fix that
    is in 4.1.1 FP4 for the alternate probe approach.
    

APAR Information

  • APAR number

    IC67861

  • Reported component name

    TPC FOR FABRIC

  • Reported component ID

    5608TC100

  • Reported release

    33W

  • Status

    CLOSED MCH

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-04-15

  • Closed date

    2010-09-13

  • Last modified date

    2010-09-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS8JFM","label":"TotalStorage Productivity Center for Fabric"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"33W","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
13 September 2010