IC65942: UNABLE TO TAB TO DROPDOWN INPUT FIELD CREATED USING GLOBAL RULE.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Unable to tab to the dropdown input field that was created using
    Glogal Rules. This input field is a combination dropdown box and
    input field.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All HATS Arabic and Hebrew users             *
    ****************************************************************
    * PROBLEM DESCRIPTION: Unable to tab to the dropdown input     *
    *                      field that was created using Global     *
    *                      Rules. This input field is a            *
    *                      combination dropdown box and input      *
    *                      field.                                  *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The Java Script function offsetTop is used to in VisualFiels.js
    to determine which line focusable input elements belong.
    By default, the focusable input element is relative to its
    parent. For input fields their parent is main HATS form.
    But for drop-down lists, their parent is the <div> in which
    they are included.  Therefore, the position is not correctly
    calculated.
    

Problem conclusion

  • VisualField.js now calculates the absolute value of offset
    from top instead of using the offsetTop Java Script function.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC65942

  • Reported component name

    RATL HATS FOR 5

  • Reported component ID

    5724U6800

  • Reported release

    750

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-01-28

  • Closed date

    2010-02-18

  • Last modified date

    2010-02-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL HATS FOR 5

  • Fixed component ID

    5724U6800

Applicable component levels

  • R750 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXKAY","label":"IBM Host Access Transformation Services"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]