IBM Support

IC65276: PCOM: PCSDB DATABASE ACCESS UTILITY DOES NOT START WITH THE MESSAGE UNSUPPORTED OPERATION WAS ATTEMPTED

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The database access utility does not start. Instead, the dialog
    box shows the message An supported operation was attempted,
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of Database Access utility         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Database Access fails to launch after   *
    *                      Personal Communications 6.0 is          *
    *                      installed.                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The Database Access tool relies on ActiveX controls that were
    removed by PCOM 6.0 install package.
    

Problem conclusion

  • Restore ActiveX controls grid32.ocx, spin32.ocx and threed.ocx
    to PCOM 6.0 install.
    
    Fix scheduled to be in PCOM 6.0.1 Manufacturing Refresh
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC65276

  • Reported component name

    PCOMM V5 COMBO-

  • Reported component ID

    5639I700J

  • Reported release

    600

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-12-22

  • Closed date

    2010-04-14

  • Last modified date

    2010-04-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • ACTIVEX
    

Fix information

  • Fixed component name

    PCOMM V5 COMBO-

  • Fixed component ID

    5639I7000

Applicable component levels

  • R600 PSY

       UP