Fixes are available
APAR status
Closed as program error.
Error description
DATA TRANSFER (both direction) have error. Can not transfer numeric packed & numeric zoned field data with 1027(unicodoe) + 1200 PC codepage combination. Case1: issue msgPCSFT219 when using HCP=1027(UNICODE) and CCSID=1399 of numeric field ( packed or zoned ) Case2: transfer will makes Incorrout data result. For search : pack packed zone zoned garbage
Local fix
Problem summary
Incorrect data length was calculated when the source data is in SBCS+DBCS+Zone+Packed ,... etc. mixed mode, so that makes incorrect index was referenced and converted to wrong data
Problem conclusion
Recalculate the data length for mixed mode data and give the correct index to convert corresponding Unicode data.
Temporary fix
Comments
APAR Information
APAR number
IC61245
Reported component name
PCOMM V5 COMBO-
Reported component ID
5639I700J
Reported release
590
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-05-26
Closed date
2009-06-18
Last modified date
2009-12-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
IP23069
Fix information
Fixed component name
PCOMM V5 COMBO-
Fixed component ID
5639I700J
Applicable component levels
R590 PSN IP23069
UP09/12/22 I 1000