IBM Support

IC59646: LABEL LIBVOL GENERATING ADSM_DD_LOG2 ERRORS IN AIX ERRPT WITH IBM 3996 AND UDO OPTICAL DRIVES

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The label libvolume command may return ADSM_DD_LOG2 errors in
    the AIX errpt when using an IBM 3996 or Plasmon G series optical
    library with UDO drives. The volumes are labeled and can be used
    without error.
    .
    Customer/L2 Diagnostics (if applicable)
    AIX errpt will show:
    LABEL:          ADSM_DD_LOG2
    IDENTIFIER:     5680E405
    Date/Time:       Fri Oct  3 01:08:39 WAUST 2008
    Sequence Number: 89285
    Machine Id:      000xxxxxxxxx
    Node Id:         NodenameX
    Class:           H
    Type:            PERM
    Resource Name:   op3
    Resource Class:  optdisk
    Resource Type:   ADSM-SCSI-OP
    Location:        U7311.D20.060662C-P1-C04-T1-L3-L0
    Description
    STORAGE SUBSYSTEM FAILURE
    Probable Causes
    ATTACHED SCSI TARGET DEVICE
    Failure Causes
    ATTACHED SCSI TARGET DEVICE
    SCSI ADAPTER
            Recommended Actions
            RUN DIAGNOSTICS AGAINST THE FAILING DEVICE
            CHECK PHYSICAL INSTALLATION
            CHECK FOR CORRECT MICROCODE FIX
            CONTACT APPROPRIATE SERVICE REPRESENTATIVE
    Detail Data
    COMMAND
    0603 0000 0000 0000 0000 0000 0000 0000
    STATUS CODE
    0000 0000
    SENSE DATA
    0102 0000 7000 0200 0000 00F6 0000 0000 0400 0000 0000 0000 1213
    0000
    0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
    0000
    0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
    0000
    FB80 00B0 FFF2 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
    0000
    0000 0000 0000 0000 0000 0000 0000 0000 ERROR CODE
    .
    Device driver tracing showed the TUR failure:
    22:50:25.694
    [723][pvrddt.c][320][pvrDdt]:unix_analyze_io_results: status =
    46 compcode = 306 num_sense = 255
    22:50:25.694
    [723][pvrddt.c][320][pvrDdt]:unix_analyze_io_results: info_valid
    = 0, info_bytes = 1
    22:50:25.694 [723][pvrddt.c][320][pvrDdt]:ds_op_ioctl:
    ADSM_OPIOC_TEST_UNIT_READY: failed,rc=46
    22:50:25.694 [723][pvrddt.c][320][pvrDdt]:dd_ioctl: unlock ok.
    22:50:25.694 [723][pvrddt.c][320][pvrDdt]:dd_ioctl:
    0xf10001002e7af000
    **ADSM_OPIOC_TEST_UNIT_READY**  END  rc 46, status 46, compcode
    306
    .
    The completion code of 306 is DD_DRIVE_OR_MEDIA_FAILURE.  Since
    this completion code means there could be something wrong with
    hardware or media the TSM device driver will log this failure to
    the OS error log.
    .
    *NOTE*
    1) The corrections are specific to UDO1/UDO2 drives.
    2)  The drive  behavior can be different on different platforms
    depending on the HBA and native driver.  This means on AIX TUR
    will fail but on Windows or other Unix TUR might not fail, hence
    the error might not be logged in the system error logs.
    .
    Platforms affected:
    TSM 5.4 and 5.5 on AIX
    .
    Initial Impact: Low
    .
    Additional Keywords: log sense ADSM_DD_LOG2 3996 Plasmon optical
    UDO2UDO1 UDO
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All TSM Server users on AIX with UDO drives. *
    *                                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: See error description.                  *
    ****************************************************************
    * RECOMMENDATION: Apply fixing level when available. This      *
    *                 problem is currently projected to be fixed   *
    *                 in 5.4.5 and 5.5.3. Note that this is        *
    *                 subject to  change at the discretion of      *
    *                 IBM.                                         *
    ****************************************************************
    *
    

Problem conclusion

  • This problem has been fixed.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC59646

  • Reported component name

    TSM SERVER

  • Reported component ID

    5698ISMSV

  • Reported release

    55A

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-01-22

  • Closed date

    2009-01-26

  • Last modified date

    2009-01-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TSM SERVER

  • Fixed component ID

    5698ISMSV

Applicable component levels

  • R54A PSY

       UP

  • R55A PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"55A","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
26 January 2009