Fixes are available
APAR status
Closed as program error.
Error description
Customer running PCOM5.9.1 on Windows O.S. Vista and they're not able to establish a TN3270 connection. The following error appears "The client and server can't communicate because they do do not possess a common algorithm.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Telnet3270 secure connection using * * Microsoft CryptoAPI (MSCAPI) as security * * package. * **************************************************************** * PROBLEM DESCRIPTION: User not able to establish a SSL * * connection using MSCAPI on Windows * * VISTA but has no problem using * * GSKit. * **************************************************************** * RECOMMENDATION: * **************************************************************** Microsoft Windows Vista has made changes to MSCAPI module Secure32.dll. Now the AcquireCredentialsHandle() API fails with error SEC_E_ALGORITHM_MISMATCH which means "The client and server cannot communicate, because they do not possess a common algorithm."
Problem conclusion
PCSMSSEC.DLL has been changed to set the default values for members in SCHANNEL_CRED structure and to verify the server Certificate Authority as "trusted" by setting the flag to SCH_CRED_MANUAL_CRED_VALIDATION in SCHANNEL_CRED structure for Windows VISTA operating systems.
Temporary fix
pcsmssec.dll
Comments
APAR Information
APAR number
IC54164
Reported component name
PCOMM V5 COMBO-
Reported component ID
5639I7000
Reported release
590
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-10-24
Closed date
2007-11-13
Last modified date
2008-10-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PCSMSSEC
Fix information
Fixed component name
PCOMM V5 COMBO-
Fixed component ID
5639I7000
Applicable component levels
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSEQ5Y","label":"Personal Communications"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.9","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]