APAR status
Closed as program error.
Error description
The macro recorder does not recognize a new host screen when "auto enter" is used. The host system advances to the next scree n but the macro recorder does not add a next screen.
Local fix
This issue can be worked around by stopping the macro recorder and starting the recording on the new next screen. Start the recording on the last key stroke and insert the new host screen.
Problem summary
**************************************************************** * USERS AFFECTED: Developers recording a macro using a 5250 * * host with an auto enter field. * **************************************************************** * PROBLEM DESCRIPTION: Recording a macro with an auto enter * * field does not record correctly. * * When you enter data into the auto * * enter field the screen is * * automatically submitted to the host * * and a new screen is displayed. * * This series of events is not recorded * * by the HATS macro recorder. * * The HATS macro recorder does not * * realize that the screen was * * submitted and that a new host screen * * is being displayed to the macro * * developer. * **************************************************************** * RECOMMENDATION: * **************************************************************** Recording a macro with an auto enter field does not record correctly.
Problem conclusion
The HATS macro recorder was updated to recognized when a screen has been automatically submitted to the host. If this happens a new screen node will be added to the macro tree.
Temporary fix
Comments
APAR Information
APAR number
IC52693
Reported component name
HATS MULTI
Reported component ID
5724L0200
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-05-14
Closed date
2007-07-12
Last modified date
2007-07-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
HATS MULTI
Fixed component ID
5724L0200
Applicable component levels
R600 PSY
UP
R700 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXKAY-2","label":"Rational Host Access Transformation Services"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]