HE11315: Wrong extremity Line when defining Flatness, Profile-of-Line or Profile-of-Surface Tolerance with common zone

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This problem does no longer occur on CXR21rel, but the customer
    has reported this as priority 1 so we need
    to create a fix on reported level.
    Scenario tested on CRX20rel NOK
    Scenario tested on CRX21rel  OK.
    .
    1. Start Catia V5
    2. Open xxxxx.CATPart
    3. Start FT&A Workbench
    4. Start Tolerancing Advisor
    5. Select two or more of the green surfaces
    6. Select Icon Flatness Specification
    Please notice: two of the generated extremity lines are pointing
     to the same surface. The last selected surface is not pointed b
    y an extremity line.
    .
    Please notice:
    The same error occurs when defining Profile-of-Line or Profile-o
    f-Surface Tolerance with common zone.
    .
    Expected result:
    If 2 planes are selected, extremity lines should point to both p
    lanes
    

Local fix

  • empty
    

Problem summary

  • This problem does no longer occur on CXR21rel, but the
    customer has reported this as priority 1 so we need
    to create a fix on reported level.
    Scenario tested on CRX20rel NOK
    Scenario tested on CRX21rel  OK.
    .
    1. Start Catia V5
    2. Open xxxxx.CATPart
    3. Start FT&A Workbench
    4. Start Tolerancing Advisor
    5. Select two or more of the green surfaces
    6. Select Icon Flatness Specification
    Please notice: two of the generated extremity lines are
    pointing to the same surface. The last selected surface is
    not pointed by an extremity line.
    .
    Please notice:
    The same error occurs when defining Profile-of-Line or
    Profile-of-Surface Tolerance with common zone.
    .
    Expected result:
    If 2 planes are selected, extremity lines should point to
    both planes
    

Problem conclusion

  • NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP7.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R21 SP2.
    Additional Closure Information:
    Technical explanation of the defect:
    Wrong extremity Line when defining Flatness, Profile-of-Line
    or Profile-of-Surface Tolerance with common zone.
    Technical explanation of the correction:
    When the leader is associative to geometry(perpendicular to
    leader) the anchor point
    of the leader should be the middle point and not the middle
    point of the previous leader so that
    the leaders are correctly aligned. Its fixed now.
    Possible by-pass or correction limitation: None
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE11315

  • Reported component name

    CATIA V5 WIN 64

  • Reported component ID

    569165000

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-10-17

  • Closed date

    2011-11-17

  • Last modified date

    2011-11-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 WIN 64

  • Fixed component ID

    569165000

Applicable component levels

  • R520 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
17 November 2011