IBM Support

HE11026: SMARTEAM VIEWER CAN NOT VIEW STANDARD PARTS IN AN ASSEMBLY

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • Environment -
    Windows XP SP2
    SmarTeam R21 SP1 + SmarTeam Viewer + PLM DB
    Scenario -
    1. Login to PLMDB_R21 as admin
    2. Select the project 'PRJ-000004 Inventor-Two Seater jet Ski'
    3. Open the documents tree of above project
    4. select the object 'ASY-0000040 - PANEL PCB Released'
    5. On profile card, click 'Viewer' tab
    ==>> In the viewer, the standard parts are not displayed.
    ==>> In the model tree of viewer you see messages indicating
    that the standard part ipt files not found.
    6. Locate that standard part in the assembly tree in the
    Editor, then click the viewer tab
    ==>> The selected standard part can be displayed in the
    viewer.
    Expected Result -
    It should be visible in Viewer.
    Additional Info -
    I have checked in R20SP6. Problem is reproducible on that as
    well.
    

Local fix

  • empty
    

Problem summary

  • Environment -
    Windows XP SP2
    SmarTeam R21 SP1 + SmarTeam Viewer + PLM DB
    Scenario -
    1. Login to PLMDB_R21 as admin
    2. Select the project 'PRJ-000004 Inventor-Two Seater jet Ski'
    3. Open the documents tree of above project
    4. select the object 'ASY-0000040 - PANEL PCB Released'
    5. On profile card, click 'Viewer' tab
    ==>> In the viewer, the standard parts are not displayed.
    ==>> In the model tree of viewer you see messages indicating
    that the standard part ipt files not found.
    6. Locate that standard part in the assembly tree in the
    Editor, then click the viewer tab
    ==>> The selected standard part can be displayed in the
    viewer.
    Expected Result -
    It should be visible in Viewer.
    Additional Info -
    I have checked in R20SP6. Problem is reproducible on that as
    well.
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN I-PLM Collaborative
    Innovation
    Additional Closure Information:
    Diagnosis: Standard Parts can not viewed in SmarTeam Viewer
    Reason: Lifecycle rules in PLMDB configured that standard
    parts does not copied upon copy file operation. To view
    Inventor assembly it is required copy all parts include
    standard parts.
    By-pass:
    Set lifecycle rule for document tree class rules as following:
    Original Operation - Copy File
    Destination Operation - Copy File (instead of No Operation)
    Original Class - Assembly
    Destination Class - Standard
    Note that this setting will copy all standard parts to user's
    work directory when open assembly from SmarTeam.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE11026

  • Reported component name

    SMARTEAM NT>XP

  • Reported component ID

    569199970

  • Reported release

    521

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-10-07

  • Closed date

    2011-11-15

  • Last modified date

    2011-11-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS2S3T","label":"ENOVIA SmarTeam V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"521","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
15 November 2011