APAR status
Closed as program error.
Error description
Scenario Licenses required:MD2+ST1+SXT 1. Launch CATIA V5 2. Create a new product ?Product1? 3. Insert -> Existing Component (click on ?Product1?) 4. Select *.cgr (attached) 5. Go To Tools / Option Click on ?STEP? sheet 6. In STEP/ Export area, select ?AP214? as Application Protocol (AP) 7. In STEP/ Export area, select ?Global nested assembly? for assemblies 8. Click on ?OK? button, Tools option panel exits 9. Select File-> SaveAs, select ?stp? for ?Save as type?, Result: .stp file is not generated correctly. It does not point to .3dxml file. .3dxml file is not generated Expected result and remarks This scenario should: - Create .stp file with a link to .3dxml file - Create .3dxml file associated to .cgr file
Local fix
empty
Problem summary
Scenario Licenses required:MD2+ST1+SXT 1. Launch CATIA V5 2. Create a new product ???Product1??? 3. Insert -> Existing Component (click on ???Product1???) 4. Select *.cgr (attached) 5. Go To Tools / Option Click on ???STEP??? sheet 6. In STEP/ Export area, select ???AP214??? as Application Protocol (AP) 7. In STEP/ Export area, select ???Global nested assembly??? for assemblies 8. Click on ???OK??? button, Tools option panel exits 9. Select File-> SaveAs, select ???stp??? for ???Save as type?? ?, Result: .stp file is not generated correctly. It does not point to .3dxml file. .3dxml file is not generated Expected result and remarks This scenario should: - Create .stp file with a link to .3dxml file - Create .3dxml file associated to .cgr file
Problem conclusion
THIS PROBLEM HAS BEEN FIXED ON V5R22 GA. THIS PROBLEM HAS BEEN FIXED ON V5R20 SP7. THIS PROBLEM HAS BEEN FIXED ON V5R21 SP2. Additional Closure Information: Technical explanation of the defect: Export STEP+3DXML KO on a V5R20 installation with ST1. Technical explanation of the correction: The software component for the translation from CGR to 3DXML was not available in the customer configuration. A copy of this component was done in a STEP FW so that the scenario works on the customer configuration. Set this variable CATDXImpExpStepWith3dxml=1 in order to get the correction.
Temporary fix
Comments
APAR Information
APAR number
HE08230
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-06-24
Closed date
2011-09-21
Last modified date
2011-09-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R520 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
21 September 2011