Error description

  • Environment -
    Windows 7 64 Bit
    SmarTeam R20SP5 + PLM DB
    SolidWorks R2011 SP0
    Settings -
    Define the "Simplified configuration extension" as "(*)" via 'Sm
    arTeam / Options... / Administrator Options' in SolidWorks.
    Scenario -
    - Create a SW-Part and save it to SmarTeam
    -> Document has been saved to SmarTeam with its Part ID and Conf
    iguration name as "Default".
    - Create an additional configuration named "Test" and perform a
    SmarTeam / Save
    -> Document has been saved with its Part ID with suffix as 001 a
    nd Configuration Name as "Test"
    - Verify the information available in the SW-Document via 'File
    / Properties' - select the Tab 'Configuration Specific'
    -> Information correctly available for the Configuration "Defaul
    t" and "Test"
    - Create an additional configuration named "Test2" and perform a
     SmarTeam / Save
    -> Document has been saved with its Part ID with Suffix as 002 a
    nd Configuration name as "Test2"
    - Verify the information available in the SW-Document via 'File
    / Properties' - select the Tab 'Configuration Specific'
    Current Result - The information for the configuration "Test2" i
    s not correct. The information available for the "ID" is "Part-I
    D-001" where it should be "Part-ID-002"
    It seems that, configurations with identical names have the same
     properties, only configurations with totally different names ha
    ve different properties.
    Expected Result - It should display the correct Information.
    Additional Info -
    If we do SmarTeam Save again and then check the "File/Properties
    ". Information gets updated.
    

Local fix

  • empty
    

Problem summary

  • Environment -
    Windows 7 64 Bit
    SmarTeam R20SP5 + PLM DB
    SolidWorks R2011 SP0
    Settings -
    Define the "Simplified configuration extension" as "(*)" via
    'SmarTeam / Options... / Administrator Options' in
    SolidWorks.
    Scenario -
    - Create a SW-Part and save it to SmarTeam
    -> Document has been saved to SmarTeam with its Part ID and
    Configuration name as "Default".
    - Create an additional configuration named "Test" and perform
    a SmarTeam / Save
    -> Document has been saved with its Part ID with suffix as
    001 and Configuration Name as "Test"
    - Verify the information available in the SW-Document via
    'File / Properties' - select the Tab 'Configuration Specific'
    -> Information correctly available for the Configuration
    "Default" and "Test"
    - Create an additional configuration named "Test2" and
    perform a SmarTeam / Save
    -> Document has been saved with its Part ID with Suffix as
    002 and Configuration name as "Test2"
    - Verify the information available in the SW-Document via
    'File / Properties' - select the Tab 'Configuration Specific'
    Current Result - The information for the configuration
    "Test2" is not correct. The information available for the
    "ID" is "Part-ID-001" where it should be "Part-ID-002"
    It seems that, configurations with identical names have the
    same properties, only configurations with totally different
    names have different properties.
    Expected Result - It should display the correct Information.
    Additional Info -
    If we do SmarTeam Save again and then check the
    "File/Properties". Information gets updated.
    

Problem conclusion

  • THE PROBLEM WAS SUBMITTED ON :
        I-PLM Collaborative Innovation VERSION V5R20.
    THIS PROBLEM IS NOT REPRODUCIBLE ON :
    I-PLM Collaborative Innovation VERSION V5R22 GA level
    I-PLM Collaborative Innovation VERSION V5R20 SP7.
    I-PLM Collaborative Innovation VERSION V5R21 SP1.
    Additional Closure Information:
    Not reproducible on R20Sp7 and above levels
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE08057

  • Reported component name

    SMARTEAM NT>XP

  • Reported component ID

    569199970

  • Reported release

    520

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-06-20

  • Closed date

    2011-08-25

  • Last modified date

    2011-08-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SMARTEAM NT>XP

  • Fixed component ID

    569199970

Applicable component levels

  • R520 PSN