IBM Support

HE07393: When Instantiate 2D Component, the behavior of scale is differen t between V5 R19 and V5 R20.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Scenario:
    1. Launch CATIA.
    2. Enable ?Tools > Options > Mechanical Design > Drafting > Anno
    tation and Dress-Up > 2D component > Create with constant size?.
    3. Drafting WB.
    4. Create a Front View with View Scale 2:1.
    5. Create a 2-D component (any).
    6. Select "Instantiate 2D Component" icon
    7. Select 2D Component.1 created.
    8. Tools Palette is opened.
    Result:
    In V5R19, value displayed in ?scale? option in Tools Palette is
    ?.5?.
    In V5R20, value displayed in ?scale? option in Tools Palette is
    ?1?
    
    Expected Result:
    The value of scale option in V5R20 should be same as that in V5R
    19.
    

Local fix

  • empty
    

Problem summary

  • Scenario:
    1. Launch CATIA.
    2. Enable ?Tools > Options > Mechanical Design > Drafting >
    Annotation and Dress-Up > 2D component > Create with constant
    size?.
    3. Drafting WB.
    4. Create a Front View with View Scale 2:1.
    5. Create a 2-D component (any).
    6. Select "Instantiate 2D Component" icon
    7. Select 2D Component.1 created.
    8. Tools Palette is opened.
    Result:
    In V5R19, value displayed in ?scale? option in Tools Palette
    is ?.5?.
    In V5R20, value displayed in ?scale? option in Tools Palette
    is ?1?
    
    Expected Result:
    The value of scale option in V5R20 should be same as that in
    V5R19.
    

Problem conclusion

  • NOTE THAT THIS PROBLEM WILL BE FIXED ON V5R22 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP7.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R21 SP1.
    Additional Closure Information:
    INCIDENT DIAGNOSIS:
    Scale and angle of the reference 2D Component and 2D
    Component instance are not shown correctly in the tools
    palette.
    CLOSURE DESCRIPTION:
    On instantiating, only the scale of the view was considered.
    On instantiating from 2D Component, scale of the reference 2D
    Component instance is now considered and the tools pallete
    values are shown accordingly.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE07393

  • Reported component name

    CAA V5 NT>XP

  • Reported component ID

    569151100

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2011-05-30

  • Closed date

    2011-07-04

  • Last modified date

    2011-07-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CAA V5 NT>XP

  • Fixed component ID

    569151100

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: