Error description

  • Scenario
    1.Create new drawing with JIS standard.
    2.Define circle and define diameter dimension.
    3.Slect dimension and select Properties from its context menu.
    4.Select Dimension line tab and Check off for Symbol2.
    Diameter dimension has one arrow symbol.
    5.Move dimension position out of the circle.
    6.Select Create/Modify Clipping command and clip the
    dimension.
    .
    Problem: Arrow Symbol disappears
    .
    Expected Result:
    Arrow symbol should not be gone even though dimension is
    clipped.
    

Local fix

  • empty
    

Problem summary

  • Scenario
    1.Create new drawing with JIS standard.
    2.Define circle and define diameter dimension.
    3.Slect dimension and select Properties from its context menu.
    4.Select Dimension line tab and Check off for Symbol2.
    Diameter dimension has one arrow symbol.
    5.Move dimension position out of the circle.
    6.Select Create/Modify Clipping command and clip the
    dimension.
    .
    Problem: Arrow Symbol disappears
    .
    Expected Result:
    Arrow symbol should not be gone even though dimension is
    clipped.
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION V5R22 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R21 SP2.
    Additional Closure Information:
    Incident Diagnosis:Drafting / Arrow disappears for Diameter
    Dimension with single arrow on clipping Dimension
    Correction Explanatiion: The problem does not occur.
    Possible By-pass:Use clipped, two symbols diameter dimension.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE07169

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-05-23

  • Closed date

    2011-07-11

  • Last modified date

    2011-07-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R521 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
11 July 2011