Error description

  • SCENARIO:
    When the mesh is activated/Updated after performing Remove
    Mesh, the mesh is not recreated and error message appear.
    Error Message
    Impossible to mesh connection Mesh Part : Contact Connection
    Mesh.1
    Projection is impossible.
    Possible causes:
    1. Connection is designed to link 2 close geometries/meshes.
     - projection tolerance = 1.41421mm as result of internal
    computation based on meshes to connect.
     - Reduce distance between geometries/meshes to get a
    connection mesh
    2. Projection sources are projection targets
    3. No source to project.
    PROBLEM:
    The mesh is not recreated when the mesh is activated or
    Updated after performing Remove Mesh.
    EXPECTED RESULT:
    The mesh which is removed by Remove Mesh function, should be
    retrieved normally after Update mesh or performing Activate /
    Deactivate on mesh.
    

Local fix

  • empty
    

Problem summary

  • SCENARIO:
    When the mesh is activated/Updated after performing Remove
    Mesh, the mesh is not recreated and error message appear.
    Error Message
    Impossible to mesh connection Mesh Part : Contact Connection
    Mesh.1
    Projection is impossible.
    Possible causes:
    1. Connection is designed to link 2 close geometries/meshes.
     - projection tolerance = 1.41421mm as result of internal
    computation based on meshes to connect.
     - Reduce distance between geometries/meshes to get a
    connection mesh
    2. Projection sources are projection targets
    3. No source to project.
    PROBLEM:
    The mesh is not recreated when the mesh is activated or
    Updated after performing Remove Mesh.
    EXPECTED RESULT:
    The mesh which is removed by Remove Mesh function, should be
    retrieved normally after Update mesh or performing Activate /
    Deactivate on mesh.
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA
    Additional Closure Information:
    .
    INCIDENT DIAGNOSIS:
    The contact connection mesh cannot be updated successfully
    after performing Remove Mesh.
    .
    RESTRICTION EXPLANATION:
    In order to create a contact connection mesh, it has to be
    possible to project a node from one surface to other, meaning
    that the two surfaces should face each other.
    However the BR data (created on R18 level) contains two faces
    that do not face each other. i.e. a Node from surface 1
    cannot be projected onto the surface 2 with normal projection
    direction.
    On R18 level, it was possible to define contact connection
    even though there is no overlap between the two surfaces.
    However such result is physically not relevant.
    Therefore a new development has been done so that operator
    does not allow user to generate such FE model. In addition,
    whenever user updates such contact connection mesh (faces
    having no overlap between them) an appropriate error message
    is thrown to educate the user about the situation.  Please
    refer QA00000005264 to know more about the contact connection
    mesh.
    .
    By-pass:
    Move the geometry so that faces will overlap i.e. a node from
    one surface can be projected on to other.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE02153

  • Reported component name

    CATIA V5 WIN 64

  • Reported component ID

    569165000

  • Reported release

    520

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-11-26

  • Closed date

    2010-12-03

  • Last modified date

    2010-12-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: