Error description

  • SCENARIO:
    1. Start CATIA V5
    2. Create a new CATPart
    CASE 1:
    3. Go into sketcher workbench and create a profile with
    following co-ordinates on XY plane.
    4. Select Profile icon and create a sketch using points at
    following co-ordinates
    Point 1 at (0, 0)
    Point 2 at (40, 0)
    Point 3 at (40, 40)
    Point 4 at (0, 40)
    Point 5 at (0, -10)
    5. Click Exit workbench
    6. Select Pad command
    7. Select the sketch (created at step 3 to 5)
    8. Click Ok
    Observation:
    Feature Definition Error
    You must use thick option in order to use an open profile,
    whenever current feature is the first solid feature of a
    body. Do you want to use the selected sketch anyway?
    9. Click Yes on error and click OK in Pad dialog box
    Observation:
    Update Error
    Part1\PartBody\Pad.1
    You must use thick option in order to use an open profile,
    whenever current feature is the first solid feature of a body
    This is correct behavior.
    .
    CASE 2
    9. Double click on sketch.1 to go into the sketch
    10. Create a line starting from (0, 0) to (0, -10) so that it
    will overlap the earlier line and select exit workbench.
    11.  Select Pad command
    12. Select the sketch
    13. Click Ok
    Observation:
    No error appears and Pad is created.-This is a problem.
    .
    PROBLEM:
    Inconsistent behavior of Pad command when profile is
    self-intersecting.
    EXPECTED RESULT:
    Behavior of Pad should be consistent and error should appear
    in both the cases.
    

Local fix

  • empty
    

Problem summary

  • SCENARIO:
    1. Start CATIA V5
    2. Create a new CATPart
    CASE 1:
    3. Go into sketcher workbench and create a profile with
    following co-ordinates on XY plane.
    4. Select Profile icon and create a sketch using points at
    following co-ordinates
    Point 1 at (0, 0)
    Point 2 at (40, 0)
    Point 3 at (40, 40)
    Point 4 at (0, 40)
    Point 5 at (0, -10)
    5. Click Exit workbench
    6. Select Pad command
    7. Select the sketch (created at step 3 to 5)
    8. Click Ok
    Observation:
    Feature Definition Error
    You must use thick option in order to use an open profile,
    whenever current feature is the first solid feature of a
    body. Do you want to use the selected sketch anyway?
    9. Click Yes on error and click OK in Pad dialog box
    Observation:
    Update Error
    Part1\PartBody\Pad.1
    You must use thick option in order to use an open profile,
    whenever current feature is the first solid feature of a body
    This is correct behavior.
    .
    CASE 2
    9. Double click on sketch.1 to go into the sketch
    10. Create a line starting from (0, 0) to (0, -10) so that it
    will overlap the earlier line and select exit workbench.
    11.  Select Pad command
    12. Select the sketch
    13. Click Ok
    Observation:
    No error appears and Pad is created.-This is a problem.
    .
    PROBLEM:
    Inconsistent behavior of Pad command when profile is
    self-intersecting.
    EXPECTED RESULT:
    Behavior of Pad should be consistent and error should appear
    in both the cases.
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA
    Additional Closure Information:
    .
    INCIDENT DIAGNOSIS:
    Inconsistent behavior of Pad command when profile is
    self-intersecting.
    .
    RESTRICTION EXPLANATION:
    When user creates additional overlapping line, the earlier
    open profile(sketch) gets closed. Then this closed sketch is
    taken as input for the Pad. Pad algorithm uses the clever
    computation by healing the edge (overlapping line) which is
    self crossed. Thus the Pad is created using the healed face
    which is correct behavior. It is not appropriate to restrict
    Pad creation and throwing an error message as profile itself
    is closed.  Furthermore it will introduce the regression in
    the other parts which are created using the healed sketches.
    .
    By-Pass:
    None
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE00927

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    520

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-10-12

  • Closed date

    2010-11-12

  • Last modified date

    2010-11-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 November 2010