APAR status
Closed as unreproducible in next release.
Error description
SCENARIO:- 1.Launch the CATIA 2.Open the given CATPart. 3.Go to Tools->Macro->Macros 4.Open the given CATVBA File. 5.Execute the Module 1 in given macro. 6.Body.2 is highlighted because an argument of CreateReferenceFromName is ?? Part1/ !Body.2??. 7.Execute ?? Module2 ?? macro in this VBA. 8.-> Body.2 is highlighted though an argument of CreateReferenceFromName is ?? Part1/ !Body.3??. . PROBLEM:- The Product.CreateReferenceFromName of Automation API makes a Reference of Object different from Object specified by the argument of this API. . EXPECTED RESULT:- CreateReferenceFromName API should make a reference of object which is passed as argument.
Local fix
empty
Problem summary
SCENARIO:- 1.Launch the CATIA 2.Open the given CATPart. 3.Go to Tools->Macro->Macros 4.Open the given CATVBA File. 5.Execute the Module 1 in given macro. 6.Body.2 is highlighted because an argument of CreateReferenceFromName is ?? Part1/ !Body.2??. 7.Execute ?? Module2 ?? macro in this VBA. 8.-> Body.2 is highlighted though an argument of CreateReferenceFromName is ?? Part1/ !Body.3??. . PROBLEM:- The Product.CreateReferenceFromName of Automation API makes a Reference of Object different from Object specified by the argument of this API. . EXPECTED RESULT:- CreateReferenceFromName API should make a reference of object which is passed as argument.
Problem conclusion
THE PROBLEM WAS SUBMITTED ON : CATIA VERSION V5R20. THIS PROBLEM IS NOT REPRODUCIBLE ON : CATIA VERSION V5R21 GA level CATIA VERSION V5R20 SP4. Additional Closure Information: Incident Diagnosis: CretaeReferenceFromName API Technical Reason: This is data specific issue and not reproducible on from scratch data macro returns correctly even on English Platform.
Temporary fix
Comments
APAR Information
APAR number
HE00186
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
520
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-09-17
Closed date
2010-09-24
Last modified date
2010-09-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R520 PSN
UP