APAR status
Closed as program error.
Error description
Prerequisites : - start I-configure - under your project select Final-Basic - select the Drawing folder - for Output Format value select smart DWG (DWG) - export your settings (file / export) Scenario : - start CV5 - make sure your project is referenced in Tools / Options - go to Piping workbench - route a run (any run) - place a pipe on this run (any pipe) - use "Generate ISO ..." command - select line ID and tick "display ISO drawing" Result : pcf and dwg are generated, but drawing is not displayed and an error message appears : "IRunNotFound" Expected Result: The drawing should be generated.
Local fix
empty
Problem summary
Prerequisites : - start I-configure - under your project select Final-Basic - select the Drawing folder - for Output Format value select smart DWG (DWG) - export your settings (file / export) Scenario : - start CV5 - make sure your project is referenced in Tools / Options - go to Piping workbench - route a run (any run) - place a pipe on this run (any pipe) - use "Generate ISO ..." command - select line ID and tick "display ISO drawing" Result : pcf and dwg are generated, but drawing is not displayed and an error message appears : "IRunNotFound" Expected Result: The drawing should be generated.
Problem conclusion
THIS PROBLEM WILL BE FIXED ON Virtual Design VERSION V5R21 GA level. Additional Closure Information: Technical explanation of the defect: While opening the drawing file only the file having .dxf extension is considered. In order to open file having .dwg extension the code should be modified. Technical explanation of the correction: The corresponding code is modified in order to open the file having extension .dwg.
Temporary fix
Comments
APAR Information
APAR number
HD99905
Reported component name
CATIA V5 WIN 64
Reported component ID
569165000
Reported release
519
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-09-09
Closed date
2010-09-20
Last modified date
2010-09-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 WIN 64
Fixed component ID
569165000
Applicable component levels
R521 PSN
UP