IBM Support

HD99844: ENOVIA V5 SELECTION OPTION DOES NOT POPUP WHEN CREATING FILTERS IN SPECIFICATIONS CATALOGS

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Enovia V5 Selection option does not popup when creating
    filters in specifications catalogs.
    This has been Ran on Both 32 and 64 bit machines.
    We open the piping specification Catalog
    (P51PipingSpecifications ---.Catalog) and
    When trying to run a query from a specification catalog, we
    manually have to key-in the path to the Enovia Part catalog.
    We have set the Options as:
    Folder                Current
    DLName             Allowed
    SmarTeam Query  Not Allowed
    ENOVIA V5 VPM  Allowed
    SmarTeam          Not Allowed
    SMARTEAM (CWI)    Not Allowed
    Catalog              Allowed
    Loaded Document    Allowed
    LINKED DOCUMENT LOCALIZATION - all options Active=Yes
    It is expected that when we click Browse, the ?option to
    select a file? pops up,  when we cancel
    We expect to see the Enovia selection option. Instead nothing
    appears.
    The user has to put the Correct entire path and select browse.
     If we plug in the path to Enovia with a ?---? and error pops
    up
    The user must remove the ?---? , click Browse, when the file
    selection menu appears, cancel it , or select off the window
    to get the filter icon to appear, else the filter icon
    remains grayed out.
    The  piping parts catalog is not file based, why is Enovia,
    VPM nav not selectable??
    

Local fix

  • empty
    

Problem summary

  • Enovia V5 Selection option does not popup when creating
    filters in specifications catalogs.
    This has been Ran on Both 32 and 64 bit machines.
    We open the piping specification Catalog
    (P51PipingSpecifications ---.Catalog) and
    When trying to run a query from a specification catalog, we
    manually have to key-in the path to the Enovia Part catalog.
    We have set the Options as:
    Folder                Current
    DLName             Allowed
    SmarTeam Query  Not Allowed
    ENOVIA V5 VPM  Allowed
    SmarTeam          Not Allowed
    SMARTEAM (CWI)    Not Allowed
    Catalog              Allowed
    Loaded Document    Allowed
    LINKED DOCUMENT LOCALIZATION - all options Active=Yes
    It is expected that when we click Browse, the ???option to
    select a file??? pops up,  when we cancel
    We expect to see the Enovia selection option. Instead nothing
    appears.
    The user has to put the Correct entire path and select browse.
     If we plug in the path to Enovia with a ???---??? and error pop
    s
    up
    The user must remove the ???---??? , click Browse, when the file
    
    selection menu appears, cancel it , or select off the window
    to get the filter icon to appear, else the filter icon
    remains grayed out.
    The  piping parts catalog is not file based, why is Enovia,
    VPM nav not selectable??
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON I-PLM Collaborative Innovation
    VERSION V5R21 GA level.
    Additional Closure Information:
    Closure report from R&D:
    Diagnosis: migrate on PLMChooser (variable
    CatalogExternalChapterFileChooser to rollback the behavior)
    We were not able to test this in the lab, customer will need
    to verify correction on their data.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD99844

  • Reported component name

    ENOVIA VPMV5 WI

  • Reported component ID

    569165400

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-09-07

  • Closed date

    2010-10-14

  • Last modified date

    2010-10-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ENOVIA VPMV5 WI

  • Fixed component ID

    569165400

Applicable component levels

  • R521 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS7P2G","label":"ENOVIA V5 VPM Discipline"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: