  • SCENARIO:
    1.Build the given workspace on R20 level.
    2.Launch the CATIA.
    3.Go to Tools-Option->Equipments &Systems->Electrical Harness
    Installation->Harness Management ,select the FLEX Algorithm.
    4.Open the V505620.CATProduct.
    5.Change workbench to the Electrical Harness Assembly
    workbench.
    6.Double click on the FLEX_LIGHT_PROTECTION_GB to activate it.
    7.Move one of the connector by compass.
    8.Select the Update All command. The info dialog appears.
    9.Click OK button.
    .
    PROBLEM:
    The computation warning report appears and the dialog info
    appears only one time.
    .
    EXPECTED RESULT:
    Dialog should appear two times when the FLEX is customized on
    CAA.
    

Local fix

  • empty
    

Problem summary

  • SCENARIO:
    1.Build the given workspace on R20 level.
    2.Launch the CATIA.
    3.Go to Tools-Option->Equipments &Systems->Electrical Harness
    Installation->Harness Management ,select the FLEX Algorithm.
    4.Open the V505620.CATProduct.
    5.Change workbench to the Electrical Harness Assembly
    workbench.
    6.Double click on the FLEX_LIGHT_PROTECTION_GB to activate it.
    7.Move one of the connector by compass.
    8.Select the Update All command. The info dialog appears.
    9.Click OK button.
    .
    PROBLEM:
    The computation warning report appears and the dialog info
    appears only one time.
    .
    EXPECTED RESULT:
    Dialog should appear two times when the FLEX is customized on
    CAA.
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION V5R21 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP4.
    Additional Closure Information:
    Technical explanation of the defect:
    Handling of FLEX segment in case of light protection is
    incomplete.
    Technical explanation of the correction:
    Handling of FLEX segment in case of Light protection has been
    improved. Now FLEX will
    succeed and dialog (customized by user) will appear for each
    FLEX segment.
    Possible by-pass and/or correction limitation
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD99218

  • Reported component name

    CATIA V5 WIN 64

  • Reported component ID

    569165000

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-08-13

  • Closed date

    2010-09-27

  • Last modified date

    2010-09-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 WIN 64

  • Fixed component ID

    569165000

Applicable component levels

  • R520 PSN

       UP