APAR status
Closed as Permanent restriction.
Error description
SCENARIO: 1. Create a new CATPart. 2. Create a simple geometry (for example, a pad feature) 3. Apply some material to the PartBody. 4. Save and close the CATPart. 5. File / Open. 6. Select the saved CATPart and activate the "Show preview" option in "Open" dialog box. OBSERVATION: The preview shows the geometry with material applied on it. EXPECTED RESULT: Preview should show the last saved status of the part. The material should not be displayed on part.
Local fix
empty
Problem summary
SCENARIO: 1. Create a new CATPart. 2. Create a simple geometry (for example, a pad feature) 3. Apply some material to the PartBody. 4. Save and close the CATPart. 5. File / Open. 6. Select the saved CATPart and activate the "Show preview" option in "Open" dialog box. OBSERVATION: The preview shows the geometry with material applied on it. EXPECTED RESULT: Preview should show the last saved status of the part. The material should not be displayed on part.
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA. Additional Closure Information: INCIDENT DIAGNOSIS: The "Show preview" Option of File-Open dialog shows the Part with Material applied, whereas in CATIA be seen with no material applied on it. RESTRICTION DETAILS: The material is stored in the document (part or product) which is root of the editor at the material application time. If we save this document on disk, this material gets saved with this File. So when we launch File-Open ,select any file and check Show Preview, it shows the preview stored in the selected File, which is with material in this case. This Preview is displayed only on Microsoft Windows and it is of the selected File. When Part is opened in CATIA ,by default no Rendering style is applied on it, so user is not able to see any material applied on Part. If user apply any Rendering style, he is able to view that particular rendering style. The behaviour seen in the Show Preview is a designed behaviour; hence this issue is considered as restriction. BYPASS: NA
Temporary fix
Comments
APAR Information
APAR number
HD99089
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
520
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-08-09
Closed date
2010-11-26
Last modified date
2010-11-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
26 November 2010