HD99086: CAPTURES BEHAVING INCORRECTLY CATIA V5 / V5R19 SP6 / WINXP

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • SCENARIO :
    1. Open the CATProduct  file in CATIA.
    2.  Activate the CATPart in the Functional Tolerancing and
    Annotation Workbench.
    3.  Expand tree and right click the Engineering Definition
    Release and select DISPLAY CAPTURE.
    Problem:
    The view is changed as compared to previous release.
    Expected result :
    The view should be the same as in the case of previous
    release.
    

Local fix

  • empty
    

Problem summary

  • SCENARIO :
    1. Open the CATProduct  file in CATIA.
    2.  Activate the CATPart in the Functional Tolerancing and
    Annotation Workbench.
    3.  Expand tree and right click the Engineering Definition
    Release and select DISPLAY CAPTURE.
    Problem:
    The view is changed as compared to previous release.
    Expected result :
    The view should be the same as in the case of previous
    release.
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON Virtual Design  VERSION V5R21
    GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19 SP9.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP4.
    Additional Closure Information:
    Technical explanation of the defect:
    Position matrix not correctly applied in
    assemblyContext
    Technical explanation of the correction:
    Use the method GetOrigin etc... which take into
    account on Position matrix
    Possible by-pass and/or correction limitation:
    none
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD99086

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    519

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-08-09

  • Closed date

    2010-09-09

  • Last modified date

    2010-09-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R519 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: