HD98419: GSD: JOIN: ANGULAR THRESHOLD OPTION WORKS FOR LESS THAN 0.5 DEGR EE VALUE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • SCENARIO:
    The CATPart contains two surfaces. The angle between two
    surface is 0.2 degree.
    Create Join Of two surfaces with following option.
    Activate Check tangency option
    Activate Angular Threshold option and put 0.3 deg as value
    and Click OK.
    OBSERVATION
    Join is created without error. Angular threshold value is
    particularly useful to avoid joining overlapping elements and
    work on the top of check tangency option. Therefore there is
    no meaning that Angular threshold value can be lower than 0.5
    deg
    .
    EXPECTED RESULT:
    Angular Threshold option should not work for less than 0.5
    degree value and Error message should be displayed. Or it
    should not be possible to set Angular Threshold below 0.5 deg
    

Local fix

  • empty
    

Problem summary

  • SCENARIO:
    The CATPart contains two surfaces. The angle between two
    surface is 0.2 degree.
    Create Join Of two surfaces with following option.
    Activate Check tangency option
    Activate Angular Threshold option and put 0.3 deg as value
    and Click OK.
    OBSERVATION
    Join is created without error. Angular threshold value is
    particularly useful to avoid joining overlapping elements and
    work on the top of check tangency option. Therefore there is
    no meaning that Angular threshold value can be lower than 0.5
    deg
    .
    EXPECTED RESULT:
    Angular Threshold option should not work for less than 0.5
    degree value and Error message should be displayed. Or it
    should not be possible to set Angular Threshold below 0.5 deg
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA
    Additional Closure Information:
    .
    INCIDENT DIAGNOSIS:
    While using Join command, Angular Threshold option works for
    less than 0.5 degree value even though Check Tangency option
    works till 0.5 degrees.
    .
    RESTRICTION EXPLANATION:
    Check Tangency and Angular threshold options are completely
    different and independent.
    Check tangency option allows checking tangency continuity
    between internal edges (of a surface) as well as merged edges
    (adjacent edges of neighborhood surface) and if angle between
    edges is more than 0.5 degrees, an error is thrown.
    Angular threshold option allows to check that max angle
    between all the adjacent faces of merged cells (faces) is not
    greater than the specified value. This check works on merged
    cells only and does not work on internal edges.
    It is not appropriate to lock/restrict minimum value of
    Angular threshold value to 0.5 degrees because in some other
    cases (especially in Class A surface design) Join command is
    used with less than 0.5deg Angular threshold value. It would
    be seen as a regression for such cases.
    .
    By-Pass: None
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD98419

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    520

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-07-19

  • Closed date

    2010-07-23

  • Last modified date

    2010-07-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
23 July 2010