IBM Support

HD97996: FTA / Creation of Distance with other general tolerance than ISO 2768 is not possible.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as suggestion for future release.

Error description

  • FTA / Creation of Distance with other general tolerance than ISO
    2768 is not possible.
    (This is a Duplicate of - BR10000071048)
    .
    SCENARIO:
    1. Start CATIA and open a simple Pad with hole. (Switch to FTA W
    B).
    2. Select Tolerancing Advisor.
    3. Select the hole and select diameter option in the Semantic To
    lerancing Advisor window.
    6. The Limit of Size Definition window is seen.
    7. Select the General Tolerance
    .
    RESULTS:
    It is observed that only the ISO 2768 is available.
    User cannot use other standards than ISO 2768
    .
    EXPECTATION:
    There should be possibility for the User to use the
    other standard tolerances e. g. DIN 1680,
    DIN1683, DIN1686, DIN1688, DIN267, DIN ISO
    4759, MBN 10177, MBN 10293.
    .
    

Local fix

  • empty
    

Problem summary

Problem conclusion

Temporary fix

Comments

  • Dear Customer:  we have reviewed the problem report you
    submitted and determined that the function referenced is
    working within the scope of the original design
    specification. However we recognize the value of your
    feedback and will consider including resolution of this issue
    as a product enhancement in a future release, if one is made
    available.  We thank you for your input.
    Additional Closure Information:
    Incident Diagnosis:
    Only general tolerances defined for ISO and ANSI are proposed
    by FTA. User wants to utilize other
    general tolerances. It isn't possible up to now.
    Development Request Justification:
    The general tolerances should be integrated in the standard
    xml files so as user can add new general
    tolerances. To have that capability, Standard xml files
    structure need to be modified, and new UI is
    to be enhanced to allow user add customized general
    tolerances.
    

APAR Information

  • APAR number

    HD97996

  • Reported component name

    CATIA V5 WIN 64

  • Reported component ID

    569165000

  • Reported release

    519

  • Status

    CLOSED SUG

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-07-02

  • Closed date

    2010-08-11

  • Last modified date

    2010-08-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
11 August 2010