APAR status
Closed as user error.
Error description
Scenario: 1. Create a CATPart containing the layout of cylinder. 2. Move to the 2D layout and create a dimension for the height of the cylinder with precision of 0.01 and 1. Problem: When the dimension is created with the precision value of 1 it is rounded to lower integer (x.5 to x) Expected Result: The dimension should be rounded to upper integer X+1
Local fix
empty
Problem summary
Scenario: 1. Create a CATPart containing the layout of cylinder. 2. Move to the 2D layout and create a dimension for the height of the cylinder with precision of 0.01 and 1. Problem: When the dimension is created with the precision value of 1 it is rounded to lower integer (x.5 to x) Expected Result: The dimension should be rounded to upper integer X+1
Problem conclusion
THE PROBLEM HAS BEEN FOUND TO BE ANOTHER SYMPTOM OF THE PROBLEM REPORTED IN APAR HD48866 OR THE ANSWER MADE FOR THIS DUPLICATE APAR APPLIES ALSO TO THE CURRENT PROBLEM. Additional Closure Information: Incident Diagnosis: Rounding off is not performed correctly. Explanations: The dimension shown in this case is actually 34.4999999999864. When we are considering the 0.01 precision algorithm will consider 2 decimal places and round the dimension to 34.5 and when precision is 1.0 it will consider all the decimal point see that the value is above 34.5000000.... and round it up to the nearest integer that is 34. We are also attaching the macro so that you can use it to check the exact value of dimension as stated above in the SR. Open the 2DL of the file create the dimension, run the macro and then click on the dimension.
Temporary fix
Comments
Incident Diagnosis Some dimensions have for real values ab.x499999999995 and some other ab.x500000000003. These little precision problems comes form computer calculations. rounded to 10-6 (and up to 10-2), both those values give ab.x5, but when you round them to 10-1, you get ab.x in the first case and ab.y, where y=x+1, in the second case. . Correct Application If the user wants to use true dimensions, then the geometry should not be designedto 0.5*10-p if the dimension precision wanted is 10-p! For example, if the precision is 10-2, and the dimension wanted to create is 10.4, do not create the geometry to get a CAD dimension to 10.449xxxxx or 10.35xxxxx what ever are the xxxxx digit values. If the design has been made deliberately to this value, please use fake dimensions. Documentation Reference Getting Started
APAR Information
APAR number
HD96458
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
519
Status
CLOSED USE
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-05-18
Closed date
2011-09-20
Last modified date
2011-09-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: