IBM Support

HD96168: MEASURE INERTIA: CONTENT & PARAMETERS IN THE TREE, EDIT WINDOW & F(X) ARE DIFFERENT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • ABSTRACT:
    Measure Inertia: Content & Parameters in the tree, edit
    window & f(x) are different.
    .
    SCENARIO:
    1. Launch CATIA V5R19SP5 & Go to
    Tools/Options/General/Parameter and Measure and then select
    "With value" & "With formula".
    2. Create new part with Enable Hybrid design.
    3. Create a sketch & extrude it.
    4. Use measure inertia select the Part Body.
    5. Select Keep Measure & in customize; select only Area,
    Volume, Density & Mass.
    6. Since only surface is created , InertiaSurface.1 displayed
    with Area, Surface Mass & Mass values. Click OK.
    7. Now go to Part design workbench & modify the contents of
    Part Body by adding thickness to create a solid.
    8. Update the Inertia Surface.1. we see there is difference
    between Displayed parameters in the tree & parameters in the
    Edit window for measure inertia (with double click
    InertiaSurface.1 ), Volume parameter is added in edit window
    but in tree & also f(x) we don?t have Volume parameter ? This
    is the problem.
    9. Now create a new inertia measurement (InertiaVolume.1) by
    selecting the Part body (Area, Volume, Density & Mass
    parameters appear in tree).
    10. Delete the contents of the Part body & update the
    InertiaVolume.1 , the Volume values in the tree are not
    changing to zero - This is the problem.
    .
    RESULT:
    All the parameters (especially Volume in this case) in the
    Specification tree, Edit window & in f(x) for measured
    inertia properties are not same & do not represent
    updated/modified correct values of these parameters at any
    moment.
    EXPECTED RESULT:
    All the parameters (especially Volume in this case) in the
    Specification tree, Edit window & in f(x) for measured
    inertia properties should be same & represent
    updated/modified correct values of these parameters at any
    moment.
    

Local fix

  • empty
    

Problem summary

  • ABSTRACT:
    Measure Inertia: Content & Parameters in the tree, edit
    window & f(x) are different.
    .
    SCENARIO:
    1. Launch CATIA V5R19SP5 & Go to
    Tools/Options/General/Parameter and Measure and then select
    "With value" & "With formula".
    2. Create new part with Enable Hybrid design.
    3. Create a sketch & extrude it.
    4. Use measure inertia select the Part Body.
    5. Select Keep Measure & in customize; select only Area,
    Volume, Density & Mass.
    6. Since only surface is created , InertiaSurface.1 displayed
    with Area, Surface Mass & Mass values. Click OK.
    7. Now go to Part design workbench & modify the contents of
    Part Body by adding thickness to create a solid.
    8. Update the Inertia Surface.1. we see there is difference
    between Displayed parameters in the tree & parameters in the
    Edit window for measure inertia (with double click
    InertiaSurface.1 ), Volume parameter is added in edit window
    but in tree & also f(x) we don???t have Volume parameter ??? Thi
    s
    is the problem.
    9. Now create a new inertia measurement (InertiaVolume.1) by
    selecting the Part body (Area, Volume, Density & Mass
    parameters appear in tree).
    10. Delete the contents of the Part body & update the
    InertiaVolume.1 , the Volume values in the tree are not
    changing to zero - This is the problem.
    .
    RESULT:
    All the parameters (especially Volume in this case) in the
    Specification tree, Edit window & in f(x) for measured
    inertia properties are not same & do not represent
    updated/modified correct values of these parameters at any
    moment.
    EXPECTED RESULT:
    All the parameters (especially Volume in this case) in the
    Specification tree, Edit window & in f(x) for measured
    inertia properties should be same & represent
    updated/modified correct values of these parameters at any
    moment.
    

Problem conclusion

  • THIS PROBLEM WAS REPORTED ON CATIA V5R19SP5.
    THIS PROBLEM WILL BE FIXED IN NEXT RELEASE WHICH IS CATIA
    V5R21GA & V5R20SP3.
    Additional Closure Information:
    Incident Diagnosis
    Measure Inertia: Content & Parameters in the tree, edit
    window & f(x) are different.
    Explanation
    This problem is closed as FIN on CATIA V5R19 level. So this
    problem is now fixed on CATIA V5R20SP3 & CATIA V5R21GA
    levels.
    The problem is corrected now and the content & parameters in
    the Specificatio tree, edit window and f(x) are same now.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD96168

  • Reported component name

    CATIA V5 WIN 64

  • Reported component ID

    569165000

  • Reported release

    519

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-05-10

  • Closed date

    2010-06-11

  • Last modified date

    2010-06-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • R519 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
11 June 2010