IBM Support

HD95323: SMARTEAM SAVE ON SOLIDWORKS ASSEMBLY SOMETIMES FAILS WITHOUT ERR OR. THIS RESULTS IN MISSING TREE LINKS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Scenario :-
    Configurations of SmarTeam:
    - Option 'Save derived configurations' in SmarTeam SolidWorks
    integration is disabled.
    - Create first part and save to SmarTeam (SWP-0405.sldprt,
    Active part)
    - Create second part and save to SmarTeam (SWP-0406.sldprt,
    Suppressed part)
    - Create assembly, insert both SMP-0405.sldprt and
    SWP-0406.sldprt.
    - Suppress part SWP-0406.sldprt in assembly
    - Create derived configuration in assembly, but reactivate
    default configuration.
    - Save assembly to SmarTeam (SWA-0113.sldasm, Assembly with
    derived config and suppressed part)
    - Check-in assembly and parts.
    - Open assembly read-only. The active part will also be
    copied to the workdirectory, but the suppressed part not.
    - Select the suppressed part in the SolidWorks feature
    manager tree, and click the 'Open' icon. The SmarTeam
    integration will detect the missing file and will ask if it
    should look for it in the SmarTeam database. Choose 'Yes'.
    The suppressed part is copied from the vault and   opened in
    SolidWorks
    - Close the assembly and the part.
    - Delete the file of the suppressed part using the Windows
    Explorer, not the SmarTeam File Explorer!
    - The suppressed part will be marked 'Absent' in the SmarTeam
    File Explorer.
    - Open the assembly.
    - Switch to the DMT. Only the assembly is shown.
    - Click on the assembly in the DMT using the right mouse
    button and choose 'Refresh.
    - The tree is now complete [This is Current Result]
    Note:-The number of times you have to refresh the DMT is
    dependent on the number of suppressed components in the
    assembly.
    

Local fix

  • empty
    

Problem summary

  • Scenario :-
    Configurations of SmarTeam:
    - Option 'Save derived configurations' in SmarTeam SolidWorks
    integration is disabled.
    - Create first part and save to SmarTeam (SWP-0405.sldprt,
    Active part)
    - Create second part and save to SmarTeam (SWP-0406.sldprt,
    Suppressed part)
    - Create assembly, insert both SMP-0405.sldprt and
    SWP-0406.sldprt.
    - Suppress part SWP-0406.sldprt in assembly
    - Create derived configuration in assembly, but reactivate
    default configuration.
    - Save assembly to SmarTeam (SWA-0113.sldasm, Assembly with
    derived config and suppressed part)
    - Check-in assembly and parts.
    - Open assembly read-only. The active part will also be
    copied to the workdirectory, but the suppressed part not.
    - Select the suppressed part in the SolidWorks feature
    manager tree, and click the 'Open' icon. The SmarTeam
    integration will detect the missing file and will ask if it
    should look for it in the SmarTeam database. Choose 'Yes'.
    The suppressed part is copied from the vault and   opened in
    SolidWorks
    - Close the assembly and the part.
    - Delete the file of the suppressed part using the Windows
    Explorer, not the SmarTeam File Explorer!
    - The suppressed part will be marked 'Absent' in the SmarTeam
    File Explorer.
    - Open the assembly.
    - Switch to the DMT. Only the assembly is shown.
    - Click on the assembly in the DMT using the right mouse
    button and choose 'Refresh.
    - The tree is now complete [This is Current Result]
    Note:-The number of times you have to refresh the DMT is
    dependent on the number of suppressed components in the
    assembly.
    

Problem conclusion

  • NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19 SP8.
    Additional Closure Information:
    PER
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD95323

  • Reported component name

    SMARTEAM NT>XP

  • Reported component ID

    569199970

  • Reported release

    519

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-04-12

  • Closed date

    2010-05-12

  • Last modified date

    2010-06-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SMARTEAM NT>XP

  • Fixed component ID

    569199970

Applicable component levels

  • R519 PSN SP51908

       UP10/06/10 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS2S3T","label":"ENOVIA SmarTeam V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
10 June 2010