APAR status
Closed as suggestion for future release.
Error description
Abstract: When CATPRoduct save with "Propagate Security" when there is no authority in projects that the registered component has linked, the Documents-Projects link to Project that parents Product link isn't made, and the wrong message is displayed. Preparation: 1. Start System Configuration Editor 2. Search CATIA.Link. 3. Select CATIA.LinkTomainClass. 4. Select Add. 5. Set value to YES on domain level. 6. Press Save. 7. Return to search result. 8. Select CATIA.LinkAllTomainclass 9. Select Add 10. Set value to YES on domain level. 11. Press Save. 12. Press logout. 13. Start Admin console. (Login joe) 14. Start User Maintenance. 15. Select Users icon. 16. Press Add. 17. Fill test in User Login field, then press OK. User test belongs to no group 18. Start and Login Smarteam (User: joe) 19. Select "Mobile Phone Development" on project tree and select "Project Based Authorization" on contextual menu. 20. Press edit on Project Based Authorization window. 21. Add test to Project manager role. 22. Press close. 23. Select "Jet Ski Original Development" on project tree and select "Project Based Authorization" on contextual menu. 24. Press edit on Project Based Authorization window. 25. Add test to Designer role. And then close window. 26. Open the document tree of "Mobile Phone Development(ID:Project-0062)" 27. Select Document and Select Add Folder on contextual menu. 28. Press OK. Select "Secure Fold-0040? by Project -0062,Mobile Phone Development" and then press Yes. 29. Open document tree of "Jet Ski Original Development" (ID:Project-0048)" 30. Drag "Four-stroke BE-C color/02" and drop to top of document tree. 31. Select Yes to All. 32. Select "Four-stroke BE-C color/02" (created at step6), and then select Associated with Project. 33. Select Propagate and then select Yes to ALL. 34. Exit SmarTeam. Scenario: 1. Start CATIA V5 2. Create New Product.. 3. Connect SmarTeam. (login test) 4. Selct Insert component under Assembly Management of Smarteam integration menu. 5. Select CATIA Part and press modify. Set State to Released on Search by attribute window. Then press Run 6. Select Oil Tank from search result, and press ok. * Oil Tank is linked with "Project-0048 Jet Ski Original Development" and protected in project. 7. Activate top of product and select save under smarteam menu. 8. Select Project-0062 Mobile Phone Development on Project manager window and select secured folder. And select Propagate security and then press save. ==> KO!! Error message "The logged in user(test) does not have a role definition in project ?Project-0062?." is displayed. But user test assign a Project Manager Role. ? And though CATIA.LinkAllTomainclass set to Yes, the link of Documents-Projects is not created. Expected Result: When CATProduct save with "Propagate Security" when there is no authority in projects that the registered component has linked, the Documents-Projects link to Project that parents Product link is made (Protection doesn't propagate), and the message is not displayed.
Local fix
empty
Problem summary
Problem conclusion
Temporary fix
Comments
Dear Customer: we have reviewed the problem report you submitted and determined that the function referenced is working within the scope of the original design specification. However we recognize the value of your feedback and will consider including resolution of this issue as a product enhancement in a future release, if one is made available. We thank you for your input. The issue is closed as HL on R20 Stream The planing SP is SP7 - this is NOT a commitment. Additional Closure Information: Dear Customer: we have reviewed the problem report you submitted and determined that the function referenced is working within the scope of the original design specification. However we recognize the value of your feedback and will consider including resolution of this issue as a product enhancement in a future release, if one is made available. We thank you for your input. The issue is closed as HL on R20 Stream The planing SP is SP7 - this is NOT a commitment.
APAR Information
APAR number
HD93821
Reported component name
SMARTEAM NT>XP
Reported component ID
569199970
Reported release
519
Status
CLOSED SUG
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-02-21
Closed date
2010-10-11
Last modified date
2010-10-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS2S3T","label":"ENOVIA SmarTeam V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
11 October 2010