Error description

  • Scenario:
    1. Open a new product. Product1 window is displayed.
    
    2. Select the Product1 on the tree and Insert -> New Part.
    
    3. Click MB3 on the created Part -> Part Object -> Open in
    New Window. Part1 is open in new window.
    4. Click MB3 on Compass -> Edit. Parameters for Compass
    Manipulation dialog box is displayed.
    5. Input any values (ex. 1mm) for Along U, Along V, Along W
    of Increments option.
    
    6. Click Close.
    
    7. Window -> Product1.
    
    8. Click MB3 on Compass -> Edit. Then the values which input
    at step5 is kept in Increments option.
    9. Drag the compass to Part1 component in geometry area and
    move to any position. Then the compass moves freely. This is
    problem.
    .
    Expected result:
    
    Compass should not be moved freely even if Increments option
    value(s) are inherited in assembly.
    .
    Note:
    
    If we try to move the compass in Part1 window with the
    Increments option, it rejected with Move Error, but not in
    Product.
    .
    

Local fix

  • empty
    

Problem summary

  • Scenario:
    1. Open a new product. Product1 window is displayed.
    
    2. Select the Product1 on the tree and Insert -> New Part.
    
    3. Click MB3 on the created Part -> Part Object -> Open in
    New Window. Part1 is open in new window.
    4. Click MB3 on Compass -> Edit. Parameters for Compass
    Manipulation dialog box is displayed.
    5. Input any values (ex. 1mm) for Along U, Along V, Along W
    of Increments option.
    
    6. Click Close.
    
    7. Window -> Product1.
    
    8. Click MB3 on Compass -> Edit. Then the values which input
    at step5 is kept in Increments option.
    9. Drag the compass to Part1 component in geometry area and
    move to any position. Then the compass moves freely. This is
    problem.
    .
    Expected result:
    
    Compass should not be moved freely even if Increments option
    value(s) are inherited in assembly.
    .
    Note:
    
    If we try to move the compass in Part1 window with the
    Increments option, it rejected with Move Error, but not in
    Product.
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION V5R21 GA level.
    AND ALSO CORRECTED ON V5R20 SP02 LEVEL.
    .
    Additional Closure Information:
    Incident Diagnosis:
    Compass moves freely even with increment option(s) of the
    Parameters for Compass Manipulation in assembly.
    .
    Correction Explanation:
    The incremental values which are input to the part opened in
    new window are not inherited by the assembly in other window.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD93429

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    519

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-02-08

  • Closed date

    2010-03-26

  • Last modified date

    2010-03-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R521 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
26 March 2010