IBM Support

HD93258: PART: INSTANTIATION OF UDF IS DIFFERENT IN V5R19 THEN ON V5R17 W ITH RESPECT TO THE NAMING OF UDF OUTPUT FEATURES

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • .
    SCENARIO:
    1. Create a CATPart on V5R17 level with User Defined Feature
    (UDF)
    2. In the UDF define few other outputs other than mainresult
    3. Save the CATPart
    4. Start CATIA V5R19SP06 level and open the CATPart saved in
    step 3
    5. Instantiate the UDF
    .
    OBSERVATION1:
    Naming of the output profile (Other outputs defined in Step
    2) is correct and do not have any auto numbering
    .
    6. Create similar UDF on V5R19SP06
    7. Instantiate the UDF
    .
    PROBLEM:
    Naming of the output profile (Other outputs defined in Step
    2) is appended with auto numbering like xyz.1. Due to this
    auto numbering scripting fails which relies on feature naming
    .
    EXPECTED RESULT:
    Naming of UDF features/parameters (profile) should not have
    auto numbering
    

Local fix

  • empty
    

Problem summary

  • .
    SCENARIO:
    1. Create a CATPart on V5R17 level with User Defined Feature
    (UDF)
    2. In the UDF define few other outputs other than mainresult
    3. Save the CATPart
    4. Start CATIA V5R19SP06 level and open the CATPart saved in
    step 3
    5. Instantiate the UDF
    .
    OBSERVATION1:
    Naming of the output profile (Other outputs defined in Step
    2) is correct and do not have any auto numbering
    .
    6. Create similar UDF on V5R19SP06
    7. Instantiate the UDF
    .
    PROBLEM:
    Naming of the output profile (Other outputs defined in Step
    2) is appended with auto numbering like xyz.1. Due to this
    auto numbering scripting fails which relies on feature naming
    .
    EXPECTED RESULT:
    Naming of UDF features/parameters (profile) should not have
    auto numbering
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON Virtual Design  VERSION V5R21
    GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19 SP8.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP2.
    Additional Closure Information:
    .
    Technical explanation of the defect:
    Name of User Defined Feature outputs is incorrect : it has an
    auto generated number index when it should not have
    .
    Technical explanation of the correction:
    The attribute holding the output name was incorrectly removed
    which it induced a recalculation of the name and gave
    inconsistent results. Now the problem have been fixed and
    there is not auto generated number index
    .
    Possible by-pass and/or correction limitation:
    None
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD93258

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    519

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-02-03

  • Closed date

    2010-03-15

  • Last modified date

    2010-06-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R519 PSN SP51908

       UP10/06/10 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
10 June 2010