IBM Support

HD93044: CURRENTLY, ENOVIA IS NOT SIMPLIFYING THE EFFECTIVITY ON THE PART INSTANCE CONFIGURATION TAB, ALTHOUGH THE AVAILABILITY IS NOT RE

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Create a product - PRC
    Configure it
    Create a Category and add two specifications ? I used Red and
    Blue
    Create an action and add effectivity of
          R(1 ? 9900) and CATEGORY|Red
    or R(88-9900) and CATEGORY|Blue
    Send the product to the product editor with this action and
    mod attached
    Add an instance.
    The effectivity is now
     R(1 ? 9900) and CATEGORY|Red
    or R(88-9900) and CATEGORY|Blue
    Now create another action
    Add the PRC as an associated object
    Create a mod with the effectivity of  R(88-9900) and
    CATEGORY|Blue and CATEGORY|not Red
    (to get the NOT red you have to right click on the spec in
    the selection panel).
    At R19SP3 ? the effectivity was simplified to R(1-9900) AND
    CATEGORY|Red
    At R19REL the effectivity is:
    R(1-9900 AND Category|Red
    or (R(88-9900) AND CATEGORY|Blude AND CATEGORY|Red
    

Local fix

  • empty
    

Problem summary

  • Create a product - PRC
    Configure it
    Create a Category and add two specifications ??? I used Red and
    Blue
    Create an action and add effectivity of
          R(1 ??? 9900) and CATEGORY|Red
    or R(88-9900) and CATEGORY|Blue
    Send the product to the product editor with this action and
    mod attached
    Add an instance.
    The effectivity is now
     R(1 ??? 9900) and CATEGORY|Red
    or R(88-9900) and CATEGORY|Blue
    Now create another action
    Add the PRC as an associated object
    Create a mod with the effectivity of  R(88-9900) and
    CATEGORY|Blue and CATEGORY|not Red
    (to get the NOT red you have to right click on the spec in
    the selection panel).
    At R19SP3 ??? the effectivity was simplified to R(1-9900) AND
    CATEGORY|Red
    At R19REL the effectivity is:
    R(1-9900 AND Category|Red
    or (R(88-9900) AND CATEGORY|Blude AND CATEGORY|Red
    

Problem conclusion

  • NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19 SP7
    Additional Closure Information:
    This problem will also be corrected at R20SP1 and R21GA.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD93044

  • Reported component name

    ENOVIA V5 VPM N

  • Reported component ID

    569151400

  • Reported release

    519

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-01-28

  • Closed date

    2010-03-15

  • Last modified date

    2010-03-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ENOVIA V5 VPM N

  • Fixed component ID

    569151400

Applicable component levels

  • R519 PSN

       UP