IBM Support

HD92365: CATIA SESSION TERMINATES WHILE EDITION OF COPING IN CASE OF BROK EN LINK TO POINTED DOCUMENT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Scenario:
    1. Launch CATIA V5 R19 SP6 and go to SR1 workbench
    2. Create a Transverse Bulkhead limited by two Decks in
    Design Unit
    3. Execute PPE keeping nibbling option ON
    4. Observe that the link to pointed document (Deck Plate) is
    synchronized
    5. Save and close the CATProduct
    6. Change the name of one Deck CATPart
    (e.g.Deck_001.1.CATPart to Deck_001_TESTCD.1.CATPart) in
    windows explorer, so that link is broken
    7. Open CATProduct and observe broken link
    8. Through Contextual Menu execute Modify/Delete Coping
    Concern: CATIA crashes
    Expected Result : CATIA should not crash
    

Local fix

  • empty
    

Problem summary

  • Scenario:
    1. Launch CATIA V5 R19 SP6 and go to SR1 workbench
    2. Create a Transverse Bulkhead limited by two Decks in
    Design Unit
    3. Execute PPE keeping nibbling option ON
    4. Observe that the link to pointed document (Deck Plate) is
    synchronized
    5. Save and close the CATProduct
    6. Change the name of one Deck CATPart
    (e.g.Deck_001.1.CATPart to Deck_001_TESTCD.1.CATPart) in
    windows explorer, so that link is broken
    7. Open CATProduct and observe broken link
    8. Through Contextual Menu execute Modify/Delete Coping
    Concern: CATIA crashes
    Expected Result : CATIA should not crash
    

Problem conclusion

  • NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19 SP7.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP1.
    Additional Closure Information:
    Technical explanation of the defect:
    CATIA terminates when coping feature having broken link to
    pointed element is edited.
    Technical explanation of the correction:
    List of liming elemtents for a operated element was accessed
    with incorrect index. Now
    the correct index is passed.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD92365

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    519

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-01-04

  • Closed date

    2010-01-04

  • Last modified date

    2010-02-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R519 PSN SP51907

       UP10/02/24 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
24 February 2010