HD88954: ELECTRICAL (EWR) / WIRE ROUTING FAILS WITH BUNDLE SEGMENTS FROM EXTERNAL CURVE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • Scenario:
    .
    1. Unzip the contents into a suitable directory
    2. Start CATIA, and adjust Electrical Repository in
       TOOLS/OPTIONS/Equipment & systems/Electrical Process
       Interfacing tab, to point to the directory where the unzipped
       files are contained (defined as suitable directory at step 1)
    3. Switch to the Electrical Wire Routing tab, and verify that
       set Bend radius according to the wires is set to Never
    4. Then press OK to close TOOLS/OPTIONS
    5. In CATIA open the ASSY.CATProduct from the directory created
       at step1
    6. Switch to the Electrical Wire Routing workbench if not
       already active
    7. Select the New Bundle command, and then select the bundle
       in the geometry area, and finish the command by pressing OK
    8. Press the Select External Systems command
    9. Select the available system (1), press the top arrow (2),
       and then press OK (3)
    10. Press the Automatic Wire Routing command
    11. In the Wire and Wire group routing dialogue, press the top
       arrow to select the wires
    12. Then press the Route button
    
    ERROR: Automatic Routing indicates that wires cannot be
    routed. The report indicates that routes cannot be found for
    any wires.
    
    EXPECTED BEHAVIOUR: The Automatic Wire Routing
    export should indicate that all wires are successfully routed
    Update command should be done correctly
    
    
    NOTE1:
    Network assistant indicates that all segments are connected.
    Also a search for Electrical.'Bundle Segment'.'fully
    connected'=FALSE indicates that all segments are indeed
    connected
    NOTE2:
    If no Bundle Segments are created based on the external curves
    ( Entryline1-3 ) of the manifold, and the adjacent segments
    are directly connected to the manifold - the routing is
    successful. This potential workaround is however unacceptable
    as it will lead to incorrect length.
    

Local fix

Problem summary

  • Scenario:
    .
    1. Unzip the contents into a suitable directory
    2. Start CATIA, and adjust Electrical Repository in
    TOOLS/OPTIONS/Equipment & systems/Electrical Process
    Interfacing tab, to point to the directory where the unzipped
    files are contained (defined as suitable directory at step 1)
    3. Switch to the Electrical Wire Routing tab, and verify that
    set Bend radius according to the wires is set to Never
    4. Then press OK to close TOOLS/OPTIONS
    5. In CATIA open the ASSY.CATProduct from the directory
    created at step1
    6. Switch to the Electrical Wire Routing workbench if not
    already active
    7. Select the New Bundle command, and then select the bundle
    in the geometry area, and finish the command by pressing OK
    8. Press the Select External Systems command
    9. Select the available system (1), press the top arrow (2),
    and then press OK (3)
    10. Press the Automatic Wire Routing command
    11. In the Wire and Wire group routing dialogue, press the
    top arrow to select the wires
    12. Then press the Route button
    13. ERROR: Automatic Routing indicates that wires cannot be
    routed. The report indicates that routes cannot be found for
    any wires.
    1. EXPECTED BEHAVIOUR: The Automatic Wire Routing Report
    should indicate that all wires are successfully routed
    .Update command should be done correctly
    .
    1. NOTE1: Network assistant indicates that all segments are
    connected. Also a search for Electrical.'Bundle
    Segment'.'fully connected'=FALSE indicates that all segments
    are indeed connected
    2. NOTE2: If no Bundle Segments are created based on the
    external curves ( Entryline1-3 ) of the manifold, and the
    adjacent segments are directly connected to the manifold -
    the routing is successful. This potential workaround is
    however unacceptable as it will lead to incorrect length.
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA
    Additional Closure Information:
    The harness is made of Branches, Connectors and Mounting
    Equipments. The Mounting Equipment contains curves that are
    used as external curves for some Branches and three Bundle
    Connection Points. This is not the kind of use the Mounted
    Equipment is designed for. In fact, all the Bundle Connection
    Points of a Mounting Equipment are considered as connected.
    This improper use of Mounting Equipment and the automatic
    data cleaner of Wire Routing command leads to a model where
    the Wires fail to be routed.
    .
    Bypass:
    1. Remove the Bundle Connection Points (Electrical
    publications) from the Mounting Equipment reference or Do not
    use the Check Network option in the Wire Routing.
    2. Deactivate the Mounting Support and perform the wire
    routing.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD88954

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    519

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-09-18

  • Closed date

    2009-11-27

  • Last modified date

    2009-11-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
27 November 2009