Error description
SCENARIO: SETTINGS: 1) Tools / Options / General / Parameters and Measure / Units / Area = Square millimeter (mm2) 2) Tools / Options / General / Parameters and Measure / Knowledge / Parameter Tree View / with value = ON 3) Tools / Options / Infrastructure / Part Infrastructure / Display / Display in Specification Tree / Parameters = ON . 1) Start CATIA V5 2) Open the CATPart. Workbench: Product Data Filtering. 3) Click "Formula" command. "Formula" window is displayed. 4) Create "Area" as New Parameter of type. 5) Select Area.1 parameter, and click "Add Formula" command. "Formula Editor" window is displayed. 6) Input the formula: area (BODY\surface.1) 7) Click "OK" button. "Formula Editor" window is closed. "Automatic update" window is displayed. 8) Click "OK" button. "Automatic update" window is closed. 9) Click "OK" button. "Formula" window is closed. . OBSERVATION: Value displayed: Area.1 = 559029.128mm2 . 10) Click "Part to Part" command. "Part to Part" window is displayed. 11) Activate all options, and click "OK" button. Part to Part" window is closed. New Part (data1_AllCATPart) is created. 12) Click "Formula" command. "Formula" window is displayed. 13) Create "Area" as New Parameter of type. 14) Select Area.1 parameter, and click "Add Formula" command. "Formula Editor" window is displayed. 15) Input the formula: area (BODY\surface.1) 16) Click "OK" button. "Formula Editor" window is closed. "Automatic update" window is displayed. 17) Click "OK" button. "Automatic update" window is closed. 18) Click "OK" button. "Formula" window is closed. . OBSERVATION: Value displayed: Area.1 = 559028.9mm2 . OBSERVATION: The "Formula" result of area is different after filtering. The area is 559029.128mm2 before filtering. The area is 559028.9mm2 after filtering. .
Local fix
Problem summary
SCENARIO: SETTINGS: 1) Tools / Options / General / Parameters and Measure / Units / Area = Square millimeter (mm2) 2) Tools / Options / General / Parameters and Measure / Knowledge / Parameter Tree View / with value = ON 3) Tools / Options / Infrastructure / Part Infrastructure / Display / Display in Specification Tree / Parameters = ON . 1) Start CATIA V5 2) Open the CATPart. Workbench: Product Data Filtering. 3) Click "Formula" command. "Formula" window is displayed. 4) Create "Area" as New Parameter of type. 5) Select Area.1 parameter, and click "Add Formula" command. "Formula Editor" window is displayed. 6) Input the formula: area (BODY\surface.1) 7) Click "OK" button. "Formula Editor" window is closed. "Automatic update" window is displayed. 8) Click "OK" button. "Automatic update" window is closed. 9) Click "OK" button. "Formula" window is closed. . OBSERVATION: Value displayed: Area.1 = 559029.128mm2 . 10) Click "Part to Part" command. "Part to Part" window is displayed. 11) Activate all options, and click "OK" button. ?Part to Part" window is closed. New Part (data1_AllCATPart) is created. 12) Click "Formula" command. "Formula" window is displayed. 13) Create "Area" as New Parameter of type. 14) Select Area.1 parameter, and click "Add Formula" command. "Formula Editor" window is displayed. 15) Input the formula: area (BODY\surface.1) 16) Click "OK" button. "Formula Editor" window is closed. "Automatic update" window is displayed. 17) Click "OK" button. "Automatic update" window is closed. 18) Click "OK" button. "Formula" window is closed. . OBSERVATION: Value displayed: Area.1 = 559028.9mm2 . OBSERVATION: The "Formula" result of area is different after filtering. The area is 559029.128mm2 before filtering. The area is 559028.9mm2 after filtering. .
Problem conclusion
THE PROBLEM WAS SUBMITTED ON : Virtual Design VERSION V5R19. THIS PROBLEM IS NOT REPRODUCIBLE ON : Virtual Design VERSION V5R21 GA level Virtual Design VERSION V5R20 SP1. Additional Closure Information: .
Temporary fix
Comments
APAR Information
APAR number
HD88654
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
519
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-09-10
Closed date
2009-12-15
Last modified date
2009-12-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R519 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
15 December 2009